FILTER REPLACEMENT
CAUTION: Turn off the air clearner
and unplug the electrical cord before
performing any maintenance.
Filter Replacement
The CHECK FILTER indicator will
signal when to replace the entire Filter
Cassette. The replacement period will
vary depending on the hours of usage, air
quality, and location of the unit. However,
in most cases of normal use the filter will
need to be replaced annually.
Change the Filter Cassette when the
CHECK FILTER indicator is on.
This filter should be disposed of when
changed.
Filter Cassette Replacement
1. Turn off the air cleaner and unplug the
electrical cord.
2. Remove the front panel by pulling gently
from the lower portion of the panel. Do not
force, the panel should remove easily.
3. Remove the Filter Cassette by gently
pulling out from the bottom and down
from the top.
4. Remove the plastic wrap from the filter.
5. Install the Filter Cassette by inserting tabs
up into the air cleaner and gently pushing
in at the bottom tab until the frame fits into
place snuggly.
6. Replace the front panel by hooking the
panel on the top of the unit. Swing the
panel in by pushing gently on each side of
the unit and then lock it into place.
7. Plug in air cleaner and press POWER
button until short “beep” sounds.
8. Press the RESET FILTER button by gently
inserting a paperclip into the RESET
FILTER hole on the control panel. The light
will flash 5 times before a “beep” sounds
to indicate the filter has been reset. See
figure C on page 8 or Diag. 9 to the right.
The air cleaner will take 3-4 minutes to
calibrate the AIR QUALITY sensor. During
this time the sensor lights will flash on and
off. Once the sensor has calibrated, the
lights will stop flashing and the unit will begin
in AUTO mode.
OPERATIONS
CONTROL PANEL
A. AIR QUALITY SENSOR: Automatically monitors the air quality level and adjusts fan speed
accordingly in Auto.
B. AUTO Mode: Changes the mode setting to AUTO.
C. RESET: Resets the CHECK FILTER indicator light.
D. CHECK FILTER: Signals when to replace filters.
E. PlasmaWave™: Shows that PlasmaWave™ Technology is active.
F. AIR QUALITY: Green, yellow, and red lights indicate the quality of the air.
G. Turbo / High / Med / Quiet: Shows current fan speed setting.
H. SPEED: adjusts fan speed to QUIET, MED, HIGH or TURBO.
I. : Turns the unit On and Off.
J. LIGHT SENSOR: dims the control panel lights and sets the fan speed to QUIET when the
room is dark.
AUTO Mode: The unit is set to AUTO mode when it is first turned on. The air cleaner will actively
monitor the air and adjust the fan speed accordingly to quickly remove any impurities detected.
When the room is dark, the light sensor will automatically switch the unit to QUIET fan speed and
dim the control panel lights.
MANUAL OPERATION: After you turn on the unit, you can switch to manual operation by using
the SPEED button. To go back to the automatic operation press AUTO.
QUIET, MED OR HIGH: These levels are recommended for standard daytime use. HIGH will
activate automatically when sensors detect poor air quality in AUTOMATIC OPERATIONS. Use the
SPEED button to select the required level.
TURBO: This is the highest fan speed. It can be activated manually for maximum air purification
by pushing the SPEED button until the light by Turbo is illuminated.
PlasmaWave™: Push the Auto button for 3 seconds to turn on or off.
Filter Replacement and Cleaning
Filter Service life Cleaning Cycle How to clean
Washable
Pre filter
12 month
every 3 month
Washable
HEPA filter
12 month every 3 month
Washable AOC™
Carbon filter
12 month every 3 month
Filter
Cassette
12 month
-
Clean with vacuum cleaner or soft brush, Use a
lukewarm water when the filter is very dirty
Put the filter into the lukewarm water for
30 minutes and dry it out in the shade for 24 hours
-
Put the filter into the lukewarm water for
30 minutes and dry it out in the shade for 24 hours
11 12
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Winix U450EU wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info