Cleaning and service
Pull out the power plug prior to cleaning. Never immerse the
kettle and the base in water. Briefly rinse the kettle from time
to time. Wipe the outside of the appliance only with a damp
cloth. Do not use harsh or abrasive cleaning agents.
The mesh filter in the spout can be removed for cleaning
when the lid is open. To do so, press the top lug downwards.
To reinsert the mesh filter, position the mesh filter in the middle
of the spout and then push forward to lock into place. The he-
ater bottom is made of stainless steel. If you notice rust marks
nevertheless, these are only deposits sticking to the surface.
Remove them immediately with a cleaning agent for stainless
steel.
Decalcifying
Calcium deposits result in energy losses and impair the service
life of the appliance. The appliance will switch off prematurely
if the calcium deposits are too strong. It is then very difficult to
remove the deposits. Decalcify the appliance regularly.
Therefore, the pot should be regularly descaled with usual
descaling agents suitable for stainless steel. Please consider the
user instructions of the manufacturer. Pour out the water and
rinse the kettle thoroughly with cold tap water. Do not heat up
the kettle during the decalcification process.
Important. Warranty compensation does not exist for damage
that occurs due to non-compliance with the decalcification
instructions.
Causes of faults
· The appliance switches off before boiling
There are excessive calcium deposits on the bottom
of the kettle, or
· The appliance does not switch off
Close the cover until it locks into place.
The mesh filter is not correctly fitted.
· The kettle does not pour properly
Decalcify the mesh filter.
· The appliance cannot be switched on
The kettle has not cooled down sufficiently after
being operated with no or too little water.
If the fault cannot be remedied, you must return the appliance
for repair.
For UK use only
· This product is supplied with a 13 A plug conforming to BS
1363 fitted to the mains lead. If the plug is unsuitable for
your socket outlets or needs to be replaced, please note the
following. If the plug is a non-rewireable one, cut it from
Start-up
Prior to using for the first time, clean the inside of the kettle
thoroughly. To do so, pull the lid lock to open the lid. A mesh
filter is fitted in the spout to hold back large pieces of calcium
deposits when pouring out the water.
The section of the power cable not in use, can be wound
up and stored on the base. Connect the power plug to a
shockproof socket.
Fill in at least as much water that it can be seen in the window,
but not further than the max. mark. Close the lid and make sure
it locks into place. Otherwise the automatic boil-stop function
cannot function properly.
Place the kettle onto the base pointing in any direction. Only
then press down the ON switch under the handle. The indica-
tor light on the ON switch will indicate that the appliance is
heating up.
The ON switch will only lock into place if the kettle is positioned
on the base.
Due to the high level of power consumption during the boiling
process, you will notice an increase in noise.
Do not use the water from the initial boiling operation for food
purposes.
Automatic switch-off
A short time after the water has started to boil, the automatic
boil-stop function will switch off the appliance. If the kettle is
filled with only a small quantity of water, the switch-off time
will increase.
If you require only warm water, the heating process can be
cancelled at any time by pressing the ON switch. The appliance
will switch off automatically after the kettle is removed from
the base. If you want to reboil hot water, the appliance can be
switched on again.
For functional reasons, some condensed water may run from
the openings at the bottom of the kettle onto the rim of the
base. This is necessary for technical reasons and does not impair
the safety of the appliance.
Safety system
If the kettle is accidentally operated without water, a thermo-
stat will protect the kettle from overheating by switching off
the appliance.
Before filling in water, leave the kettle to cool down for 5-10
minutes.
If the first thermostat fails due to incorrect use, an additional
temperature limiter offers reliable protection.
BAL_waterkettle_BrandLoyalty_148x210_RZ.indd 10-11 20.04.11 16:04
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Wmf WMF 3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info