Prepare for operation
7
Greenstar 4000 – 6 720 891 171 (2020/09)
3 Prepare for operation
3.1 Sealed heating system
Appliances that can be connected to sealed heating systems are pre-
pressurised before operation, this pressure must be maintained for safe
use of the appliance.
Check regularly that the pressure is maintained.
Re-charge the system if the pressure indicator reads less than 0.8
bar.
If a permanent significant decrease or increase in pressure is shown
on the pressure indicator, contact your installer or maintenance
engineer.
Pressure indicator
Type of pressure indicator for the system pressure.
– Pressure gauge (an analogue dial showing the pressure)
– Pressure menu (a digital readout of the pressure)
Your appliance may have one or both types of methods to indicate the
system pressure. The type of method used on this appliance will be
detailed in the following section.
3.1.1 Checking the system pressure
The appliance pressure menu indicates the pressure within the heating
system during standby and operating periods.
Your installer will advise you of the optimum operating pressure.
Check the system pressure on the pressure menu.
Static pressure is when appliance is cold and has not fired for
heating or hot water. This will generally be 0.8 - 1.7 bar.
Operating pressure is when the appliance is firing for a heating
or hot water demand. This will generally be 1 - 2 bar.
Fig. 2 Checking the operating pressure
[1] Static pressure range.
[2] Operating pressure range.
[3] Pressure menu indicator.
The pressure menu can be accessed via the Boiler status screen.
Press the menu key ( ). Select and confirm Boiler status.
The screen Boiler status with a pressure menu indicator appears.
Check the system pressure on the display.
Indicator in red zone: pressure is too low or too high.
Indicator in yellow zone: pressure is low or slightly too high.
Indicator in green zone: pressure is normal.
Top up the heating water, if the pressure is low or too low.
3.1.2 Low pressure indication
Low pressure (shaded area [A]) will be indicated on the appliance:
The pressure indicator is within the area between 0 and 0.79 bar in
the pressure menu display (left hand yellow and red zone).
Additionally there is a message displayed.
Fig. 3 Low pressure indication
[A] Low pressure area
3.1.3 Constantly re-pressurising the system
Constantly having to re-pressurise the heating system should be
investigated as it is an indicator of potential leaks and the concentration
of inhibitor protection in the system will be reduced; this can result in
corrosion within the heating system, reducing efficiency and increasing
contaminates.
Check for leaks on heating system (pipework and radiator valves).
Contact your installer or maintenance engineer if a recurring
significant decrease or increase in pressure is indicated on the
pressure screen.
System pressure increasing:
If the system pressure repeatedly increases and you need to vent air
from the radiators, refer to section 9.3 "System gassing
troubleshooting", page 16.
Min Max
0010033762-001
3
1 2
0010033766-001
Fault - 1017
Pressure: 0.2 bar
System pressure
too low
A
Max
Min
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Greenstar 4000 GR4700i System wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info