Greenstar 8000 Style – 6720883871 (2021/05)
12 Energy consumption
The maximum heat output of this boiler can be adjusted to suit the exact
requirements of the building. The process of adjusting the maximum
heat output is commonly referred to as range rating. The new boiler is set
at the maximum output and should be adjusted when it is installed and
commissioned. In accordance with the standards, the declared space
heating efficiency, useful efficiency and NOx values efficiency for this
range rated boiler are not measured at the maximum output. To achieve
the published efficiency and NOx values, the gas rate should be reduced
by your installer during commissioning (Installation and Maintenance
instructions).
12.1 Product data on energy consumption
The information provided fulfills the requirements of regulations (EU) 811/2013 and (EU) 813/2013.
Specific precautions for installation, maintenance as well as recycling and/or disposal are provided within the installation and operating manuals.Read
and follow the installation and operating manuals.
Table 9 Product data on energy consumption Greenstar 8000 Style
Product data Symbol Unit 7 738 100 795/839
7 738 100 832/844
7 738 100 796/840
7 738 100 833/845
Product type GR8700iW 30 C NG/LPG
GR8700iW 30 CB NG/LPG
GR8700iW 35 C NG/LPG
GR8700iW 35 CB NG/LPG
Declared load profile XL XL
Energy Efficiency Class A A
Water heating energy efficiency class A A
Range rated heat output Prated kW 30 34
Annual energy consumption (average climate conditions) QHE kWH
Annual energy consumption QHE GJ 69 78
Annual electricity consumption AEC kWh 40 37
Annual fuel consumption AFC GJ 17 18
Seasonal space heating energy efficiency at range rated output s% 94 94
Water heating energy efficiency wh %89 87
Sound power level, indoors LWA dB 53 53
Indication about ability working only during off-peak hours No No
Special precautions to be taken during assembly, installation or
maintenance (if applicable)
product accompanying
documents
product accompanying
documents
Condensing boiler Yes Yes
Low temperature boiler No No
B1 boiler No No
Cogeneration space heater No No
Combination heater Yes Yes
Useful heat output
At rated heat output and high temperature regime P4kW 29.5 33.7
At 30% of rated heat output and low temperature regime P1kW 9.9 11.3
Useful efficiency
At rated heat output and high temperature regime 4%88.5 88.8
At 30% of rated heat output and low temperature regime 1% 98.7 98.8
Auxiliary electricity consumption
At full load elmax kW 0.067 0.048
At part load elmin kW 0.014 0.013
In standby mode PSB kW 0.001 0.001
Other items
Standby heat loss Pstby kW 0.071 0.071
Ignition burner power consumption Pign kWh
Emissions of nitrogen oxides (only gas- or oil fired) at range rated
output
NOxmg/kWh 23 25
Additional data for combination heaters
Daily electricity consumption (average climate conditions) Qelec kWh 0.180 0.168
Daily fuel consumption Qfuel kWh 21.652 22.174
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Greenstar 8000 Style GR8700iW wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info