56720819898 C 11/2017
WARNING: Some parts of your appliance, especially
the external surfaces, will be hot to touch when in
operation. Due care should be taken to prevent
burns. Keep children away from the appliance during
operation.
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
USER INFORMATION
ADDITIONAL INFORMATION BEFORE INSTALLING
YOUR MULTIFUEL STOVE
Once you determine the room in which your multifuel stove will be
installed, install a carbon monoxide alarm in the same room. This
alarm should be installed 1-3m from the stove. When mounted
on a wall it must be at least 150mm below the ceiling. When
mounted to the ceiling it must be 300mm away from all walls.
All local regulations, including those referring to national and
European standards need to be complied with when installing
the appliance.
Any air inlet grilles are to be positioned so they are not liable to
blockage.
Do not use your appliance as an incinerator. Only burn well
seasoned wood or Defra exempt smokeless fuel.
A minimum of annual maintenance is necessary to be sure
your appliance is running optimally. All maintenance must be
performed by a competent engineer or Chimney Sweep. Access
should be provided for regular cleaning of the appliance, ue gas
connector and chimney ue.
Do not operate your appliance with the fueling door open. Only
operate with the fueling door open during ignition, refueling and
removal of residue material to prevent fume spillage. Operating
with the fueling door open can cause over-ring of your appliance.
Operation with the door open can cause excess smoke.
This appliance is NOT suitable for installation in a shared ue
system.
This appliance is suitable and has been tested for intermittent
operation.
There must be no unauthorized modication of the appliance.
THE CLEAN AIR ACT 1993 AND SMOKE CONTROL
AREAS
Under the Clean Air Act local authorities may declare the whole
or part of the district of the authority to be a smoke control area. It
is an offence to emit smoke from a chimney of a building, from a
furnace or from any xed boiler if located in a designated smoke
control area. It is also an offence to acquire an “unauthorized fuel”
for use within a smoke control area unless it is used in an “exempt”
appliance (“exempted” from the controls which generally apply in
the smoke control area).
In England, appliances are exempted by publication on a list by the
Secretary of State in accordance with changes made to sections 20
and 21 of the Clean Air Act 1993 by section 15 of the Deregulation
Act 2015. Similarly in Scotland, appliances are exempted by
publication on a list by Scottish Ministers under section 50 of the
Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland, these are authorised by regulations
made by Welsh Ministers and by the Department of the Environment
respectively.
The Hanbury 4 has been recommended as suitable for use in smoke
control areas when burning wood logs or Defra exempt smokeless
fuel, when operated in accordance with these instructions and when
tted with a modication that prevents closure of the Secondary Air
control.
The Hanbury 5 has been recommended as suitable for use in smoke
control areas when burning wood logs or Defra exempt smokeless
fuel, when operated in accordance with these instructions and when
tted with a modication that prevents closure of the Secondary Air
control.
The Hanbury 8 has been recommended as suitable for use in smoke
control areas when burning wood logs or Defra exempt smokeless
fuel, when operated in accordance with these instructions and when
tted with a modication that prevents closure of the Secondary Air
control.
Further information on the requirements of the Clean Air Act can be
found here : https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act
1993 including designation and supervision of smoke control areas
and you can contact them for details of Clean Air Act requirements.
PERMANENT AIR VENT
All stoves requires an adequate air supply in order to operate safely
and efciently. In accordance with current Building Regulations the
installer may have tted a permanent air supply vent into the room
in which the stove is installed to provide combustion air. This air
vent should not under any circumstances be shut off or sealed.
SETTING UP YOUR STOVE
Make sure that the room in which the stove is set up has at least
one door or window into the outside or is directly adjacent to such a
room. Other replaces or exhaust fans must not be operated in the
same room as this stove.
STOVES GUARANTEE - REGISTRATION
Please visit the website: worcester-bosch.co.uk/guarantee so that
you can register your stove online or via the Worcester Guarantee
App. Alternatively, if you wish to register your Worcester Greenstyle
Stove Guarantee via telephone please call 03301 232 552.
Required safety distances (minimum clearances to combustible
materials.
Hanbury 4 Hanbury 5 Hanbury 8
A > 1200mm
(toward the front of
the stove)
A > 1200mm
(toward the front of
the stove)
A > 1200mm
(toward the front of
the stove)
B > 600mm (to the
side)
B > 600mm (to the
side)
B > 700mm (to the
side)
C > 750mm (to the
back)
C > 725mm (to the
back)
C > 700mm (to the
back)
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Greenstyle Hanbury wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info