809316
6
Zoom out
Zoom in
Vorherige Seite
1/16
Nächste Seite
6
ROOM THERMOSTAT
A room thermostat may be fitted for control of the central heating
temperature. It will be located in one room of the home. The method
of setting a room thermostat varies with the type and manufacture.
Refer to the instructions supplied with the room thermostat.
THERMOSTATIC RADIATOR VALVES
If thermostatic radiator valves are to be fitted to the system then
they must conform to the requirements of BS2767:1972. It is advisable
to leave one valve permanently set at maximum to prevent the boiler
short cycling.
SHOWERS, BIDETS, TAPS AND MIXING
VALVES
Standard hot and cold taps and mixing valves used with the
appliance must be suitable for operating at mains pressure. The use of
thermostatically controlled or pressure equalising shower valves will
guard against the flow of water at too high a temperature.
Hot and cold mains fed water can be supplied direct to an
overrim flushing bidet subject to local water company requirements.
With all mains fed systems the flow of water from the individual
taps will vary with the number of outlets operated simultaneously
and the cold water mains supply pressure to the property. Flow
balancing using ‘Ball-o-Fix’ type valves is recommended to avoid an
excessive reduction in flow to individual outlets.
For further information contact Worcester Heat Systems Ltd.
HOT AND COLD FLOW
If the flow of water demanded from both hot and cold service
outlets is dependent upon mains supply, it may not be possible in
some installations to operate all outlets simultaneously.
WATER MAINS FAILURE
It is important to note that in the event of a mains water supply
failure, no tap water will be available until the mains supply is
restored. Cistern fed hot water supply will stop once the cistern has
emptied but the appliance can still be used for heating provided that
the system is of the sealed system type. Open vent central heating
systems should be turned off until the supply is restored.
USE IN HARD WATER AREAS
In areas of exceptionally hard water supply it is recommended
that an In-Line scale inhibitor be fitted.
Installation should be strictly in accordance with the
requirements of the local Water Company. An isolating valve to
facilitate servicing should be incorporated.
The water hardness may be determined using the standard test
paper or by reference to the local Water Company.
Further information may be obtained from Worcester Heat
Systems Limited.
AIR SUPPLY FOR OPEN FLUED (O.F.)
APPLIANCES
Your installer will have made arrangements for an adequate
supply of fresh air to the appliance. Fresh air is required for
combustion. Do not block up any air ways which may be let into a wall
or door. Do not hang clothes or other combustible materials over the
appliance or against the flue pipe.
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester-Bosch Highflow 400 Series wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info