APPENDIX
6 720 803 688 (2012/11) 11
10 APPENDIX
10.1 COST WEIGHTING OF ELECTRICITY PRICE - GAS PRICE
GLOSSARY
OPERATING PRESSURE
The operating pressure is the pressure in the heating system.
PROGRAMMING UNIT
The programming unit ensures the automatic control of the flow
temperature subject to outside temperature (in case of weather-
compensated controllers) in conjunction with a time programme.
INSTANTANEOUS WATER HEATER PRINCIPLE
The water is heated as it flows through the appliance. The maximum
draw-off rate is quickly available, i.e. without long waiting times or
interruptions for the heat-up process.
HEATING RETURN
The heating return is the pipework that returns the heating water at a
lower temperature from the radiators/underfloor heating system etc. to
the heat source.
HEATING WATER
Heating water is the water that circulates in the heating system.
COEFFICIENT OF PERFORMANCE
The coefficient of performance , (COP), is the actual or calculated
identifier for air to water heat pumps under specified operating
conditions, similar to the standardised fuel consumption for vehicles.
The coefficient of performance describes the ratio between the
available heating energy and the power drawn by the compressor.
PRIMARY ENERGY FACTOR (PEF)
The consumption of fossil fuels is referred to as the primary energy
factor (PEF).
THERMOSTATIC VALVE
Thermostatic valves are mechanical temperature controllers that
enables a lower or higher heating water flow rate subject to ambient
temperature in order to maintain a constant temperature.
FLOW TEMPERATURE
Flow temperature is the temperature with which the heated heating
water flows from the appliance to the radiators, underfloor heating
circuits, etc.
EFFICIENCY
Efficiency describes the ratio between available output and energy
input. Under ideal circumstances, the efficiency is 1. Technical
processes always involve some losses, hence the efficiency of technical
equipment is always below 1.
Air to water heat pumps draw a large proportion of the energy [they
deliver] from the environment. This portion of energy is not described as
supplied energy, as it is free of charge. Were the efficiency under these
conditions to be calculated, it would be 1. As this would not be correct,
the coefficient of performance (COP) was introduced for air to water
heat pumps in order to describe the ratio between available or useful
energy to that which has been expended (in this case purely the working
energy). The coefficient of performance for air to water heat pumps lies
between 3 and 6.
Electricity price [P/kWh]
10.0-10.9
11.0-11.9
12.0-12.9
13.0-13.9
14.0-14.9
15.0-15.9
16.0-16.9
17.0-17.9
18.0-18.9
19.0-19.9
20.0-20.9
21.0-21.9
22.0-22.9
23.0-23.9
24.0-24.9
25.0-25.9
26.0-26.9
27.0-27.9
28.0-28.9
29.0-29.9
30.0-30.9
Gas price [P/kWh]
3.0-3.9 2.8 3.0 3.3 3.5 3.8 4.1 4.3 4.6 4.9 5.1 5.4 5.7 5.9 6.2 6.4 6.7 7.7 7.2 7.5 7.8 8.8
4.0-4.9 2.1 2.3 2.5 2.7 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 5.2 5.4 5.6 5.8 6.0 6.2
5.0-5.9 1.7 1.9 2.1 2.2 2.4 2.6 2.7 2.9 3.1 3.2 3.4 3.6 3.7 3.9 4.1 4.2 4.4 4.6 4.7 4.9 5.1
6.0-6.9 1.5 1.6 1.8 1.9 2.0 2.2 2.3 2.5 2.6 2.7 2.9 3.0 3.2 3.3 3.4 3.6 3.7 3.9 4.0 4.2 4.3
7.0-7.9 1.3 1.4 1.5 1.6 1.8 1.9 2.0 2.1 2.3 2.4 2.5 2.6 2.7 2.9 3.0 3.1 3.2 3.3 3.5 3.6 3.7
8.0-8.9 1.1 1.2 1.3 1.4 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3.0 3.1 3.2 3.3
9.0-9.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.4 2.5 2.6 2.7 2.8 2.9
10.0-10.9 0.9 0.9 1.1 1.2 1.3 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.0 2.1 2.2 2.3 2.4 2.5 2.6 2.6
11.0-11.9 0.8 0.9 1.0 1.1 1.1 1.2 1.3 1.4 1.5 1.5 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.2 2.3 2.3 2.4
12.0-12.9 0.8 0.8 0.9 1.0 1.1 1.1 1.2 1.3 1.3 1.4 1.3 1.6 1.6 1.7 1.8 1.9 1.9 2.0 2.1 2.2 2.2
13.0-13.9 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.2 1.3 1.2 1.4 1.5 1.6 1.7 1.7 1.8 1.9 1.9 2.0 2.1
14.0-14.9 0.7 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.2 1.2 1.3 1.4 1.5 1.5 1.6 1.7 1.7 1.8 1.9 1.9
15.0-15.9 0.6 0.7 0.7 0.8 0.9 0.9 1, 1.0 1.1 1.1 1.1 1.3 1.3 1.4 1.4 1.5 1.6 1.6 1.7 1.7 1.8
16.0-16.9 0.6 0.6 0.7 0.7 0.8 0.9 0.9 1.0 1.0 1.1 1.0 1.2 1.2 1.3 1.4 1.4 1.5 1.5 1.6 1.6 1.7
Table 3 Call-up example: cost weighting of electricity and gas prices
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Worcester Greenstar Plus Hybrid wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info