GROUNDING
The provision of an effective ground system is important in any successful communica-
tions station. A good ground system can contribute to station efficiency in a number of
ways:
It can minimize the possibility of electrical shock to the operator.
It can minimize RF currents flowing on the shield of the coaxial cable and the chassis of
the transceiver which may cause interference to nearby home entertainment devices or
laboratory test equipment.
It can minimize the possibility of erratic transceiver operation caused by RF feedback
or improper current flow through logic devices.
An effective earth ground system may take several forms; for a more complete discussion,
see an appropriate RF engineering text. The information presented below is intended only
as a guideline.
Inspect the ground system – inside the station as well as outside – on a regular basis so as to
ensure maximum performance and safety.
Mobile Station Grounding
Although satisfactory grounding in most installations will be achieved via the DC cable’s
negative lead and the antenna system’s coaxial cable shield, it is often recommended that
you provide a direct ground connection to the vehicle chassis at the mounting location of
the transceiver (installation using the MMB-82 Mounting Bracket will accomplish this, if
the MMB-82 itself is mounted to the vehicle’s chassis). Due to unexpected resonances
which may naturally occur in any location, improper communication system performance
may result from insufficient grounding. These symptoms may include:
RF feedback (resulting in distortion on your transmitted signal);
Unintended frequency change;
Blinking or blanking of the frequency display;
Noise pickup; and/or
Loss of memory.
Note that these conditions may occur in any communications installation. The FT-857D
includes extensive filtering designed to minimize the chance of such problems; however,
random currents set up by insufficient RF grounding can nullify such filtering. Bonding the
rear panel Ground lug of the FT-857D transceiver to the vehicle or vessel’s ground system
should clear up any such difficulties.
Vertex Standard does not recommend the use of “on glass” mobile antennas unless the
shield of the coaxial cable is securely grounded near the feedpoint of the antenna. Such
antennas frequently are responsible for the ground-related difficulties described above.
INSTALLATION
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yaesu FT-857D wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info