Page 135FT-
991
OperaTing Manual
Menu MODe
118 SCP SPAN FREQ
Function: Sets the bandwidth of the spectrum scope
sweeping.
Available Values: 50/100/200/500/1000
(
kHz
)
Default Setting: 100kHz
Description: Sets the bandwidth
(
SPAN
)
of the spectrum
scope.
119 SPECTRUM COLOR
Function: Selects the color of the Spectrum Scope dis-
play.
Available Values: BLUE/GRAY/GREEN/ORANGE/
PURPLE/RED/SKY BLUE
Default Setting: BLUE
120 WATER FALL COLOR
Function: Selects the color of the Water Fall display.
Available Values: BLUE/GRAY/GREEN/ORANGE/
PURPLE/RED/SKY BLUE/MULTI
Default Setting: MULTI
121 PRMTRC EQ1 FREQ
Function: Sets the center frequency of the low range for
the 3 band parametric microphone equalizer.
Available Values: 100 - 700
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting of the
low range of the 3 band parametric micro-
phone equalizer between
100 Hz
and
700 Hz
”.
122 PRMTRC EQ1 LEVEL
Function: Sets the gain for the low range of the 3 band
parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Adjusts the gain for the low range of the 3
band parametric microphone equalizer be-
tween “−
20 dB
” and “
+10 dB
”.
123 PRMTRC EQ1 BWTH
Function: Sets the width variation
(
“Q”
)
for the low
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the value of the width
(
Q
)
for the
low range for the 3 band parametric micro-
phone equalizer between “
1
” and “
10
”.
124 PRMTRC EQ2 FREQ
Function: Sets the center frequency for the middle range
of the 3 band parametric microphone equal-
izer.
Available Values: 700 - 1500
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting for the
middle range of the 3 band parametric mi-
crophone equalizer between “
700 Hz
and
1500 Hz
”.
125 PRMTRC EQ2 LEVEL
Function: Sets the gain for the middle range of the 3
band parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Selects the gain setting for the middle range
of the 3 band parametric microphone equal-
izer between “−
20 dB
” and “
+10 dB
”.
126 PRMTRC EQ2 BWTH
Function: Sets the width variation
(
“Q”
)
for the middle
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the width
(
“Q”
)
for the middle
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
127 PRMTRC EQ3 FREQ
Function: Sets the center frequency for the high range of
the 3 band parametric microphone equalizer.
Available Values: 1500 - 3200
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: OFF
Description: Selects the center frequency setting for the
high range of the 3 band parametric micro-
phone equalizer between “
1500 Hz
and
3200 Hz
”.
128 PRMTRC EQ3 LEVEL
Function: Sets the gain for the high range of the 3 band
parametric microphone equalizer.
Available Values: −20 - 0 - 10
(
dB
)
Default Setting: 5
Description: Selects the gain setting for the high range
of the 3 band parametric microphone equal-
izer between “−
20 dB
” and “
+10 dB
”.
129 PRMTRC EQ3 BWTH
Function: Selects the width setting
(
“Q”
)
for the high
range of the 3 band parametric microphone
equalizer.
Available Values: 1 - 10
Default Setting: 10
Description: Selects the width
(
“Q”
)
setting for the high
range of the 3 band parametric microphone
equalizer between “
1
” and “
10
”.
130 P-PRMTRC EQ1 FREQ
Function: Sets the center frequency of the low range for
the 3 band parametric microphone equalizer
when the speech processor is activated.
Available Values: 100 - 700
(
Hz
)
/OFF
(
100Hz/step
)
Default Setting: 200
Description: Activates when the speech processor is
“ON”. Adjusts the center frequency for the
low range of the 3 band parametric micro-
phone equalizer between
100 Hz
and
700 Hz
”.
137

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yaesu FT-991A wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info