1: ANTENNA ATT
2: APO
3: ARTS BEEP
4: ARTS INTERVAL
5: BANK LINK
6: BANK NAME
7: BCLO
8: BEEP EDGE
9: BEEP LEVEL
10: BEEP MELODY
11: BEEP SELECT
12: BELL RINGER
13: BELL SELECT
14: BUSY LED
15: CLOCK SHIFT
16: CW ID
17: CW LEARNING
18: CW PITCH
19: CW TRAINING
20: DC VOLTAGE
21: DCS CODE
22: DCS INVERSION
23: DTMF DELAY
24: DTMF MANUAL/AUTO
25: DTMF SELECT
26: DTMF SPEED
27: EAI
28: EAI TIME
29: EMERGENCY SELECT
30: EXTENDED MENU
31: FW KEY HOLD TIME
32: HALF DEVIATION
33: HOME VFO
34: HOME/REVERSE
35: INT MANUAL/AUTO
36: INTERNET
37: INTERNET CODE
38: INTERNET KEY
39: INTERNET MODE
40: INTERNET SELECT
41: LAMP
42: LANGUAGE
43: LCD CONTRAST
44: LCD DIMMER
45: LED LIGHT
46: LOCK
47: MEMORY FAST STEP
48: MEMORY NAME
49: MEMORY PROTECT
SET MODE
Enables/Disables the receiver Front-end Attenuator.
Setting of the Automatic Power-Off time.
Select the Beep option during ARTS
TM
operation.
Select the Polling Interval during ARTS
TM
operation.
Enables/Disables the Memory Bank Link Scan.
Stores Alpha-Numeric “Tag” for the Memory Bank.
Enables/disables the Busy Channel Lock-Out feature.
Enables/disables the Band-edge beeper while selecting the frequency by the DIAL knob.
Adjust the Beep volume level.
Create the Beep Melody for Bell ringer function.
Enables/Disables the keypad beeper.
Selects the number of Bell ringer repetitions.
Enables/Disables the Bell ringer function and its sound selection.
Enables/Disables the BUSY LED while the squelch is open.
Shifting of CPU clock frequency.
Program and activate the CW Identifier (used during ARTS
TM
operation).
Enables/Disables the CW Learning feature.
Select the CW tone pitch for the CW Learning, CW Training, and CW Identifier functions.
Enables/Disables the CW Training feature.
Indicates the DC Supply Voltage.
Setting of the DCS code.
Enables/Disables the “Inverted” DCS tone.
Selects the DTMF Autodialer Delay Time.
Enables/Disables the DTMF Autodial feature.
Programming of the DTMF Autodialer.
Selects the DTMF Autodialer Sending Speed.
Enables/Disables the Emergency Automatic ID (EAI) feature.
Sets the transmitting time of the Emergency Automatic ID (EAI) feature.
Select the alarms utilized when the Emergency function is engaged.
Enables/Disables the extended Set Mode Menu.
Set the time duration that a secondary function is active when the
[
F/W
]
key is pressed and
held to enable the secondary functions.
Reducing the Deviation level by 50 %.
Enables/Disables the function of the VFO DIAL knob, while in the Home Channel mode.
Selects the primary function of the
[
H/M
]
key (press the
[
H/M
]
key).
Enables/Disables the DTMF Autodialer feature while operating using the Internet Connec-
tion feature (WIRES
TM
).
Enables/Disables the Internet Connection feature (WIRES
TM
).
Selects the Access Number (DTMF digit) for the SRG operation of the Internet Connection
feature (WIRES
TM
).
Selects the primary function of the
[
INTERNET
]
key.
Selects the operating mode of the Internet Connection feature (WIRES
TM
).
Programming of the Access Number (DTMF code) for the FRG station of the WIRES
TM
(or
non WIRES
TM
Internet Link System) access.
Selects the LCD/Keypad Lamp mode.
Selects the language for the Set Mode selections.
Setting of the Display contrast level.
Setting of the Display brightness level.
Illuminates the white LED light continuously (useful as emergency flashlight at night).
Selects the Control Locking lockout combination.
Selects the channel step for the fast channel selection mode while in the Memory Recall
mode.
Stores “Alpha-Numeric” tags for the Memory channels.
Enables/Disables the Memory Write Protector.
SET MODE ITEM FUNCTION
ON / OFF
0.5hour - 12.0hour / OFF
IN RANGE / ALWAYS / OFF
15sec / 25sec
--
--
ON / OFF
ON / OFF
LEVEL 1 ~ LEVEL 9
(
LEVEL 5
)
--
KEY & SCAN / KEY / OFF
1Time - 20Times / CONTINUOUS
OFF / BELL /
USER BP1 / USER BP2 / USER BP3
ON / OFF
ON / OFF
--
--
400 - 1000 Hz
(
50 Hz/step
)
(
700 Hz
)
--
--
104 standard DCS codes
(
DCS 023
)
RX-NORMAL, TX-NORMAL /
RX-INVERT, TX-NORMAL /
RX-BOTH, TX-NORMAL /
RX-NORMAL, TX-INVERT /
RX-INVERT, TX-INVERT /
RX-BOTH, TX-INVERT
50ms / 250ms / 450ms / 750ms / 1000ms
MANUAL / AUTO
--
50ms / 100ms
ON / OFF
INT 1min ~ INT 9min / INT10min / INT15min /
INT20min / INT30min / INT40min / INT50min
(
INT 5min
)
BEEP / STROBE / BEEP&STROBE /
BEAM / BEEP&BEAM / CW / BEEP&CW /
CW-ID TX
ON / OFF
FW0.3sec / FW0.5sec / FW0.7sec /
FW1.0sec / FW1.5sec
ON / OFF
DISABLE / ENABLE
HOME / REV
MANUAL / AUTO
ON / OFF
DTMF 0 ~ DTMF 1, DTMF A ~ DTMF D,
DTMF , DTMF #
(
DTMF 1
)
INTERNET / INTERNET SELECT /
SET MODE
FRG / SRG
--
KEY 2sec - KEY10sec / CONTINUOUS /
OFF
(
KEY 5sec
)
ENGLISH / JAPANESE
LEVEL 1 ~ LEVEL15
(
LEVEL 7
)
LEVEL 1 ~ LEVEL 4
--
KEY / DIAL / KEY&DIAL / PTT / KEY&PTT /
DIAL&PTT / ALL
10CH / 20CH / 50CH / 100CH
--
ON / OFF
AVAILABLE VALUES
(
DEF ALT: BOLD ITALIC
)
128

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yaesu VX-8GE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info