MIDI Data Format
278 Appendix • A5000/A4000 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
5.3.1. Parameter change (object select)
0 01110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000000 $00
5 0ccccccc
object name(ASCII 16byte)
20 0ccccccc
22 0ttttttt object type
21 11110111 $F7
Functions as an object select message.
This message specifies the object.
object name is a 16-character name for each object. Program object names are the program num-
ber of each program (example: “001 “).
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
2($02) Wave data
19($13) Sequence
5.3.2. Parameter change (object edit)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000001 $01
5 0ppppppp
parameter number P1-P6(6byte)
10 0ppppppp
11 0ddddddd
data
0ddddddd
11110111 $F7
Changes the value of the object parameter specified by object select.
The parameters comply with P1, P2 — P6 in chart 2.
The number of data bytes depends on the parameter. The data section is divided into byte 1, which
is the upper nibble, and byte 2, which is the lower nibble. See chart 2 for details.
5.3.3. Parameter change (system parameter)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000010 $02
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 0ddddddd
data
0ddddddd
01110111 $F7
This message is a parameter change for system parameters.
The parameters comply with P1, P2 — P6 in chart 2.
The number of data bytes depends on the parameter. The data section is divided into byte 1, which
is the upper nibble, and byte 2, which is the lower nibble. See chart 2 for details.
5.3.4. Parameter change (switch remote)
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000011 $03
5 0ppppppp switch number
6 00000000 $00
10 00000000 $00
11 0ddddddd data
27 11110111 $F7
This message performs remote control of switches.
For the switch numbers, refer to table 2.
With the exception of switch numbers 123-127, data of $00-$3F turns the switch off, and data of
$40-$7F turns the switch on.
For switch numbers 123-127 (knob encoders), a value of 64 less than the data specifies the num-
ber of pulses which correspond to rotation (30 pulses per rotation). Positive numbers are rotation
toward the right, and negative numbers are rotation toward the left.
This message is received only.
5.3.5. Parameter request (object)
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000001 $01
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 11110111 $F7
This message requests transmission of the parameter of the specified object as a parameter
change.
The parameters comply with P1, P2 — P6 in chart 2.
This message is received only.
5.3.6. Parameter request (system parameter)
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000010 $02
5 0ppppppp
parameter number P1-P6 (6byte)
10 0ppppppp
11 11110111 $F7
This message requests transmission of a system parameter as a parameter change.
The parameters comply with P1, P2 — P6 in chart 2.
This message is received only.
5.3.7. Object Link Change
0 11110000 $F0
1 01000011 $43
2 0001nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000100 $04
5 0ccccccc
upper object name(ASCII 16byte)
20 0ccccccc
21 0ttttttt upper object type
22 0ccccccc
lower object name(ASCII 16byte)
37 0ccccccc
38 0ttttttt lower object type
39 0ddddddd data (0:link off, 1:link on)
40 11110111 $F7
Changes the link condition between specified objects (between Program and Sample/Sample
Bank Program is upper, and between Sample Bank and Sample is upper). Nothing occurs when an
object is selected which is not changeable, or which requires samples to be copied.
object name is a 16-character name for each object. Program object names are the program num-
ber of each program (example: “001 “).
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
5.3.8. Object Link Request
0 11110000 $F0
1 01000011 $43
2 0011nnnn nnnn = Device Number
3 01011000 $58 g=22,h=0
4 00000100 $04
5 0ccccccc
upper object name(ASCII 16byte)
20 0ccccccc
21 0ttttttt upper object type
22 0ccccccc
lower object name(ASCII 16byte)
37 0ccccccc
38 0ttttttt lower object type
39 0ddddddd data (0:link off, 1:link on)
40 11110111 $F7
When received the link condition between specified objects (between Program and Sample/Sam-
ple Bank Program is upper, and between Sample Bank and Sample is upper) is transmitted in
object link change format. This message is receive only.
The object type is shown in the following table.
t Data type
20($14) Program
17($11) Sample Bank
16($10) Sample
278

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yamaha A4000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Yamaha A4000

Yamaha A4000 Bedienungsanleitung - Deutsch - 296 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info