3. PROGRAM CHANGE
Data format: [CnH] -> [pp]
CnH = program event (n = channel number)
pp = Program number
CLP-511
pp VOICE NAME
00 PIANO 1
01 PIANO 2
88 CLAVINOVA TONE
05 E. PIANO 1
04 E. PIANO 2
06 HARPSICHORD
48 STRINGS
19 PIPE ORGAN 1
16 PIPE ORGAN 2
CLP-411
pp VOICE NAME
00 PIANO
88 CLAVINOVA TONE
05 E. PIANO 1
04 E. PIANO 2
06 HARPSICHORD
19 PIPE ORGAN 1
16 PIPE ORGAN 2
4. SYSTEM REALTIME MESSAGES
[rrH]
F8H: Timing clock
FAH: Start
FCH: Stop
FEH: Active sensing
Data Transmission Reception
F8H Transmitted every Received as 96-clock tempo timing
96 clocks when MIDI clock is set to External
FAH Recorder start Recorder start
FCH Recorder stop Recorder stop
FEH Transmitted every All notes are turned off if no data is
200 milliseconds received for more than 400
milliseconds
* Caution: If an error occurs during MIDI reception, the Damper, Sostenuto,
and Soft effects for all channels are turned off and an All Note Off occurs.
5. SYSTEM EXCLUSIVE MESSAGES
(1) Panel Data Transmit
Data format: [F0H] -> [43H] -> [0nH] -> [7CH] -> ... ->
[F7H]
F0H, 43H, 0nH, 7CH (n: channel number)
00H, 2EH (
data length
)
43H, 4CH, 20H, 20H (CL)
43H, 4CH, 50H, 27H, 39H, 36H (CLP ’96)
30H, 30H (version x, y)
[PANEL DATA]
[CHECK SUM (1byte)] = 0-(43H+4CH+20H+......+Data end)
F7H
• Panel Data Contents
(1) Voice
(2) Dual On/Off
(3) Dual Voice
(4) Dual Balance
(5) Dual Detune
(6) Dual Voice1 Octave
(7) Dual Voice2 Octave
(8) Dual Voice1 Effect Depth
(9) Dual Voice2 Effect Depth
(10) Dual Slow-attack Strings On/Off (CLP-511)
(11) Split On/Off (CLP-511)
(12) Split Voice (CLP-511)
(13) Split Point (CLP-511)
(14) Split Balance (CLP-511)
(15) Split Voice1 Octave (CLP-511)
(16) Split Voice2 Octave (CLP-511)
(17) Split Voice1 Effect Depth (CLP-511)
(18) Split Voice2 Effect Depth (CLP-511)
(19) Split Damper Mode (CLP-511)
(20) Reverb Type 1
(21) Reverb Depth 1
(22) Effect Type 1
(23) Effect Type 2
(24) Effect Depth
(25) - - -
(26) Variation 1 On/Off
(27) Variation 2 On/Off
(28) Touch Sensitivity
(29) Touch Volume in the FIXED Mode
(30) Left Pedal (Soft/Start)
(31) - - -
(32) Absolute tempo low byte
(33) Absolute tempo high byte
(34) - - -
(2) Universal Realtime Message
Master Volume
Data format: [F0H] -> [7FH] -> [XnH] -> [04H] -> [01H] ->
[ll] -> [mm] -> [F7H]
F0 = Exclusive status
7F = Universal Realtime
7F = ID of target device
04 = Sub-ID #1=Device Control Message
01 = Sub-ID #2=Master Volume
ll = Volume LSB
mm = Volume MSB
F7 = End of Exclusive
or
F0 = Exclusive status
7F = Universal Realtime
XN = When N is received N=0~F, whichever is received.
x = don’t care
04 = Sub-ID #1=Device Control Message
01 = Sub-ID #2=Master Volume
ll = Volume LSB
mm = Volume MSB
F7 = End of Exclusive
(3) Universal Non-Realtime Message
General MIDI Mode On
Data format: [F0H] -> [7EH] -> [XnH] -> [09H] -> [01H] ->
[F7H]
F0 = Exclusive status
7E = Universal Non-Realtime
7F = ID of target device
09 = Sub-ID #1=General MIDI Message
01 = Sub-ID #2=General MIDI On
F7 = End of Exclusive
or
F0 = Exclusive status
7E = Universal Non-Realtime
XN = When N is received N=0~F, whichever is received.
X = don’t care
09 = Sub-ID #1=General MIDI Message
01 = Sub-ID #2=General MIDI On
F7 = End of Exclusive
When the General MIDI mode ON message is received, the MIDI
system will be reset to its default settings.
This message requires approximately 50ms to execute, so suffi-
cient time should be allowed before the next message is sent.
(4) XG Native Parameter Change
Data format: [F0H] -> [43H] -> [1nH] -> [4CH] -> [hh] ->
[mm] -> [ll] -> [dd] -> [F7H]
F0 = Exclusive status
43 = YAMAHA ID
1n = When n is received n=0~F, whichever is received.
When n is transmitted n always=0.
4C = Model ID of XG
hh = Address High
mm = Address Mid
ll = Address Low
dd = Data
|
F7 = End of Exclusive
Data size must match parameter size (2 or 4 bytes).
When the XG System On message is received, the MIDI system
will be reset to its default settings.
The message requires approximately 50ms to execute, so suffi-
cient time should be allowed before the next message is sent.
* When program change reception is turned OFF in the Function
mode, no program change data is transmitted or received.
de datos MIDI
48

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yamaha CLP-511 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Yamaha CLP-511

Yamaha CLP-511 Bedienungsanleitung - Deutsch - 56 seiten

Yamaha CLP-511 Bedienungsanleitung - Englisch - 54 seiten

Yamaha CLP-511 Bedienungsanleitung - Portugiesisch - 36 seiten

Yamaha CLP-511 Bedienungsanleitung - Spanisch - 56 seiten

Yamaha CLP-511 Bedienungsanleitung - Schwedisch - 41 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info