<INSTALLATION AND OPERATING PRECAUTIONS FOR TIIS FLAMEPROOF EQUIPMENT>
2
IM 01F06A00-01EN
(5) Gaps between joint surfaces
The physical distance between two mating
surfaces, or differences in diameters if the mating
surfaces are cylindrical.
Note: The permissible sizes of gaps between joint surfaces,
the path length of a joint surface and the number of joint
threads are determined by such factors as the enclosure’s
internal volume, joint and mating surface construction,
and the explosion classi cation of the speci ed gases and
vapours.
4. Installation of Flameproof Apparatus
(1) Installation Area
Flameproof apparatus may be installed, in
accordance with applicable gases, in a hazardous
area in Zone 1 or 2, where the speci ed gases are
present. Those apparatus shall not be installed in a
hazardous area in Zone 0.
Note: Hazardous areas are classi ed in zones based upon
the frequency of the appearance and the duration of an
explosive gas atmosphere as follows:
Zone 0: An area in which an explosive gas atmosphere
is present continuously or is present for long
periods.
Zone 1: An area in which an explosive gas atmosphere is
likely to occur in normal operation.
Zone 2: An area in which an explosive gas atmosphere
is not likely to occur in normal operation and if it
does occur it will exist for a short period only.
(2) Environmental Conditions
The standard environmental condition for the
installation of ameproof apparatus is limited to
an ambient temperature range from –20°C to
+40°C (for products certi ed under Technical
Criteria). However, some eld-mounted
instruments may be certi ed at an ambient
temperature up to +60°C as indicated on the
instrument name plates. If the ameproof apparatus
are exposed to direct sunshine or radiant heat
from plant facilities, appropriate thermal protection
measures shall be taken.
5. External Wiring for Flameproof
Apparatus
Flameproof apparatus require cable wiring for
their electrical connections. For cable wiring, cable
glands (cable entry devices for ameproof type) to
wiring connections shall be attached. All non-live
metal parts such as the enclosure shall be securely
grounded. For details, refer to the “USER’S
GUIDELINES for Electrical Installations for
Explosive Gas Atmospheres in General Industry,”
published in 1994.
(1) Cable Wiring
For cable wiring, cable glands (cable entry
devices for ameproof type) speci ed or
supplied with the apparatus shall be directly
attached to the wiring connections to complete
sealing of the apparatus.
Screws that connect cable glands to the
apparatus are those for G-type parallel pipe
threads (JIS B 0202) with no sealing property.
To protect the apparatus from corrosive gases
or moisture, apply nonhardening sealant
such as liquid gaskets to those threads for
waterproo ng.
• Speci c cables shall be used as recommended
by the “USER’S GUIDELINES for Electrical
Installations for Explosive Gas Atmospheres in
General Industry,” published in 1994.
In necessary, appropriate protective pipes
(conduit or exible pipes), ducts or trays shall
be used for preventing the cable run (outside
the cable glands) from damage.
To prevent explosive atmosphere from being
propagated form Zone 1 or 2 hazardous
location to any different location or non-
hazardous location through the protective pipe
or duct, apply sealing of the protective pipes in
the vicinity of individual boundaries, or ll the
ducts with sand appropriately.
When branch connections of cables is made,
a ameproof or increased-safety connection
box shall be used. In this case, ameproof or
increased-safety cable glands meeting the
type of connection box must be used for cable
connections to the box.
169

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yokogawa DYA Vortex Flow Converter wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info