9-6
IM 1F5B2-01E
9.3 Option Specifications
Option Specifications (for model UYF200, UYFA21)
Item
Specifications
Code
Electrical Classification
JIS Flameproof Ex d IIC T6 Certified by TIIS (Note 2).
JF1
JIS Flameproof Packing Adapter
Electrical connection should be : G1/2 female thread.
Applicable Cable φ8.5 to φ11.
PG5
Stainless Steel Bolt & Nut Assembly
Used when a wafer type is installed for a process.
Material SUS304.
BLT
Stainless Steel Tag Plate SUS304 tag plate hung on converter case. SCT
Paint Color Change Only for converter covers. Refer to Table 9.2.1. See Table 9.2.1
Material Certificate
Reproduced material certificate for body from material
manufacture.
M01
Static Pressure and Leakage Test
Certificate
Refer to Table 3 for Pressure test value.
Test time 10 minutes.
T01
Degrease Treatment (Note 5) The body is cleaned by trichloroethylene. K1
Epoxy Coating Epoxy coating for meter case and cover. X1
Converter Installing Direction
180° Change
Converter installing direction
180° change inversely when shipped.
CRC
Accuracy ± 0.5% Type
In the case of JIS Flame proof (/JF1), specify JIS G1/2 female for electrical connection and also specify in the option code with Flameproof
packing adapter (PG5) for the cable wire construction.
TIIS is the abbreviation of Technology Institution of Industrial Safety
The JIS G1/2 female is not applicable for electrical connection.
• In case of specifying JIS Flameproof Explosion proof type, JIS G1/2 female is applied for wiring connection.
• Specify in the option code with Flame proof packing ground (/PG5) for the cable wire construction.
In case of specifying FM explosion proof type, ANSI 1/2 NPT female is applied for wiring connection.
In case of specifying CENELEC explosion proof type, ANSI 1/2 NPT female, DIN Pg 13.5female or ISO M20ϫ1.5 female is applied for
wiring connection.
In case of specifying CSA explosion proof type, ANSI 1/2 NPT female is applied for wiring connection.
There is a case that a little calibration water should stay in the meter tube. So this is not degrease treatment in strict sense.
When this option is chosen, the output is set at low level (3.6 mA) when burn-out. Otherwise is set at over high level (21.6 mA) at shipping.
Model UYF202J (25 mm), UYF215J (150mm), UYF220J (200mm) is not applicable.
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Note 10:
For accuracy guaranteed range refer item “Sizing”. HAC
Applicable Model
UYF200 wafer type
All Models
All Models
UYF200J
UYF200J
UYF200J
All Models
Lightning Protector
There is an arrester is inside converter for power supply line.
Max. power supply voltage: 30 VDC
A
UYF200J-A
UYFA21J
Down-Scale burnout in case of CPU failure
(Note 6)
Set output under 3.6 mA (low) when burn-out occurred. C1
UYF200J-A
UYFA21J
UYF200J
UYF200J (Note 7)
KF1
KS1
CENELEC Explosion Proof Type
CENELEC Intrinsic Safety type
All Models (Note 1)
All Models (Note 6)
All Models ( Note 3,6)
All Models
FM Flameproof Explosion proof type
FM Intrinsic Safety type
CSA Intrinsic Safety type
All Models (Note 5)
All Models (Note 5)
All Models (Note 7)
FF1
FS1
CS1
74

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Yokogawa UYFA21 Ultrasonic Vortex Flowmeter wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info