If the supply gas pressure is changeable or different from
the necessary pressure, you must fit an applicable pres-
sure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-pass screw po-
sition. If you change from natural gas 20 mbar to liq-
uid gas, fully tighten the adjustment screw in. If you
change from liquid gas to natural gas 20 mbar, undo
the by-pass screw approximately 1/4 of a turn.
1
1
Minimum adjustment screw
5. Make sure the flame does not go out when you quick-
ly turn the knob from the maximum position to the
minimum position.
Electrical connection
Ground the appliance according to safety precautions.
Make sure that the rated voltage and type of power on
the rating plate agree with the voltage and the power of
the local power supply.
This appliance is supplied with a mains cable. It has to
be supplied with a correct plug, able to support the
load marked on the identification plate. The plug has to
be fitted in a correct socket.
Any electrical component must be installed or replaced
by the Service Force Centre technician or qualified
service personnel.
Always use a correctly installed shockproof socket.
Make sure that there is an access to the mains plug af-
ter installation.
Do not pull the mains cable to disconnect the appli-
ance. Always pull the mains plug.
The appliance must not be connected with an extension
cable, an adapter or a multiple connection (risk of fire).
Check that the ground connection is in conformity with
the standard and regulations force.
The power cable must be placed in such a way that it
does not touch any hot part.
Connect the appliance to the mains with a device that
lets to disconnect the appliance from the mains at all
poles with a contact opening width of minimum 3 mm,
eg. automatic line protecting cut-out, earth leakage
trips or fuse.
None of a parts of the connection cable can not get a
temperature 90 °C. The blue neutral cable must be
connected to the terminal block label with "N". The
brown (or black) phase cable (fitted in the terminal
block contact marked with "L") must always be connec-
ted to the live phase.
Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90
or equivalent type. Make sure that the cable section is ap-
plicable to the voltage and the working temperature. The
yellow/green earth wire must be approximately 2 cm lon-
ger than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
550 mm
min. 600 mm
30 mm
470 mm
min. 600 mm
10 mm
11 mm
11 mm
A
3 mm
15
15

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zanussi ZGL 63IT wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info