540059
36
Zoom out
Zoom in
Vorherige Seite
1/40
Nächste Seite
36
PG-003_v02
Before installing make sure that the local distribution
conditions (the type of gas, its pressure) and the
appliance adjustment are compliant.
The conditions of gas adjustment of the appliance are
indicated on the nameplate.
The appliance is not connected to the fumes conduits.
It should be installed and connected according to
the binding installation regulations. The appropriate
requirements concerning ventilation should be taken into
consideration.
The exible gas connection shall be assembled such
way, that it is not in contact with the furniture parts in
move (i.e. drawer) and it shall be not located in the are
with not enough space.
The wiring supplying the power to the hob shall be
secured with properly selected safety device.
Upon installing the hob, the installer is obliged to check
the tightness of the gas tting.
REMARK: The installer is obliged to ll in the warranty
card, which is the basis for the warranty and guaranty.
Replacing the nozzles for the other
type of gas (Fig. B)
ATTENTION: The hob nozzles replacing can be
executed only by an authorised quali ed installer.
The gas hob is the nozzles are defaulted for 2E (G20) gas.
The other kinds of gas are:
BURNER GAS PRESSURE NOZZLE
MARKING
THERMAL
CAPACITY
WOK
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1.36
0.86
3300 W
LARGE
2E (G20)
3B/P (G30)
20 mbar
37 mbar
1.18
0.72
2500 W
MEDIUM
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0.92
0.58
1500 W
SMALL
2E (G20)
3B/P (G30)
20 mbar
37 mbar
0.75
0.49
1000 W
1
Remove the cap and crown.
2
Unscrew the nozzle using a special spanner.
3
Replace the nozzle screwing the appropriate one
according to the table.
After the nozzles exchange adjust the burners (see
”FLAME ADJUSTMENT”.
Upon nozzles replacement glue an adequate label
indicating the gas type near the end of shaft connecting
the hob manifold.
Technical speci cation
The technical parameters of the hob are indicated at the
nameplate of the appliance.
The hob is equipped with a shaft with threaded end of G1/2”
diameter for connecting to gas supply tting. In case of
connection to LPG cylinder (propane –butane) the ending
of the exible hose
8 x 1mm is screwed on the threaded
shaft end.
The gas hob is the 1st class appliance equipped with
a connecting cord with protecting stand. It requires
connection to the socket equipped with an earth pin.
the appliance meets the requirements of the standards in
force.
The appliance is in conformance with the requirements of the
following directives:
Appliances burning gaseous fuels – 90/396/EEC,
93/68/EEC.
Low Voltage Devices (LVD) – 2006/95/EC.
Electromagnetic compatibility (EMC) – 2004/108/EC.
The product has been labelled with CE mark on the
nameplate.
The appliance outline (Fig. D)
1
Large burner Ø 100 mm 2.5 kW
2
Medium burner Ø 75 mm 1.5 kW
3
Small burner Ø 55 mm 1.0 kW
4
WOK burner Ø 130 mm 3.3 kW
5
Burner control knobs with electric ignition candle
6
Burner grate
7
Burner cap
8
Burner crown
9
Burner body
10
Ignition candle
11
Anti-gas ow security device
Flame adjusting (Fig. C)
1
Switch on the burner and set the minimum ame .
2
Remove the ring knob from the spindle.
3
Adjust the ame turning the screw inside the spindle with
an appropriate screwdriver.
Check if the ame is not off in case of fast switching
from
maximum to minimum ame.
In case of 3B/P (G30) gas, the screw must be screwed
until it turns(clockwise).
36

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zelmer ZPG6054MP wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info