ANNEX II. COMMUNICATION OBJECTS
“Functional range” shows the values that, with independence of any other values permitted by the bus according to the object size, may be of any use or have a particular meaning because of the
specifications or restrictions from both the KNX standard or the application program itself.
1st boot” shows the cases where an object is assigned a certain value by the application program after a device download or a full reset. In case the value of such assignment can be
parameterised, is shown in column “P”. Objects showing a hyphen (-) are not assigned a particular value and therefore can be assumed to be initialised with the value “0”, or with the
corresponding updated value in case they depend on an external element (sensors, etc.). Moreover, if the object is sent (or is there an option to send it) to the bus (write or read requests) after a
download or a device reset from ETS, the marks (W) or (R) will be shown, respectively for transmissions or read requests.
Reboot” shows the cases where an object is assigned a certain value by the application program after a bus power failure. In case the value of such assignment can be parameterised, is shown
in column “P”. Objects showing a hyphen (-) are not assigned a particular value and therefore can be assumed to maintain their previous value after the failure, or with the corresponding updated
value in case they depend on external elements. Moreover, if the object is sent (or is there an option to send it) to the bus (write or read requests) after a bus failure, the marks (W) or (R) will be
shown, respectively for transmissions or read requests.
Number
Size
I/O
Flags
Data Type (DPT)
Functional Range
1st boot
P
Reboot
P
Name
Function
0, 1, 2, 3, 4, 5
1 Bit
I/O
C - R W U
DPT_Switch
0/1
-
-
[Ind x] Binary Indicator
1-bit generic indicator
1 Byte
I/O
C - R W U
DPT_Value_1_Ucount
0 - 255
-
-
[Ind x] Enum Indicator
1-byte enumeration
2 Bytes
I/O
C - R W U
9.xxx
-671088.64 670760.96
-
-
[Ind x] Float Indicator
2-byte float value
1 Byte
I/O
C - R W U
DPT_Value_1_Ucount
0 - 255
-
-
[Ind x] 1-byte Indicator
1-byte generic indicator
1 Byte
I/O
C - R W U
DPT_Scaling
0% - 100%
-
-
[Ind x] Scaling Indicator
Scaling value
6, 14, 22, 30
1 Bit
I/O
C T R W U
DPT_Switch
0/1
-
-
[P1][Bx] Binary Control
1-bit generic control
1 Bit
O
C T R - -
DPT_Switch
0/1
-
-
[P1][Bx] Binary Control: Hold
1-bit generic control
1 Bit
I/O
C T R W U
DPT_Switch
0/1
-
-
[P1][Bxy] Binary Control
1-bit generic control
1 Bit
I/O
C T R W U
DPT_Switch
0/1
-
-
[P1][Bxy] Light On/Off
0=Off; 1=On
1 Bit
O
C T R - -
DPT_UpDown
0/1
-
-
[P1][Bxy] Move Shutter
0=Up; 1=Down
1 Bit
I/O
C T R W U
DPT_Switch
0/1
-
-
[P1][Bx] Light On/Off
0=Off;1=On
1 Bit
O
C T R - -
DPT_Switch
0/1
-
-
[P1][Bx] Timed switch control
1-bit generic control
7, 15, 23, 31
1 Bit
O
C T R - -
DPT_Switch
0/1
-
-
[P1][Bx] Binary Control: Release
1-bit generic control
1 Bit
O
C T R - -
DPT_Step
0/1
-
-
[P1][Bxy] Stop Shutter
0 or 1 -> Stop
1 Bit
I
C - - W -
DPT_Enable
0/1
-
-
[P1][Bx] Timer enable
0=Disable; 1=Enable
8, 16, 24, 32 4 Bit O
C T R - -
DPT_Control_Dimming
0x0 (Stop)
0x1 (Dec.by 100%)
0x2 (Dec.by 50%)
0x3 (Dec.by 25%)
- -
[P1][Bxy] Light Dimming 4-bit dimming control
45

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zennio Roll-ZAS Touch Controller wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Zennio Roll-ZAS Touch Controller

Zennio Roll-ZAS Touch Controller Bedienungsanleitung - Deutsch - 49 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info