I TRANSPORTATION
Take the following measures to avoid fuel leakage during the transportation of
the heater:
Let the heater cool down.
Remove the removable tank
º from the heater and remove the fuel filter
(Fig. K). Some drops may leak from the filter; keep a cloth at hand. Store the
fuel filter and the removable tank outside the heater.
Place the transportation cap into the position of the fuel filter (Fig. L).
Press it tight.
Always move the heater in an upright position.
J SPECIFICATIONS
Ignition electrical Dimensions (mm) width 428
Fuel paraffin
(including base plate)
depth 295
Capacity (kW)
*
3.0 height 513
Suitable space (m
3
)
**
85-110 Accessories: manual fuel pump
Fuel consumption (l/hr)
*
0.313 fuel cap cover
Fuel consumption (g/hr)
*
250 transportation cap
Burning time per tank (hr)
*
13 Required batteries
2x R20kG, MN 1300
Capacity removable tank (litres) 4.0 1.5V, size D
Weight (kg) 9.0 Wick type F
* At maximum setting
** Specified values are indicative
K WARRANTY PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
We expressly dismiss all other claims for damages, including consequential
damages.
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
The warranty will no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.