L: A blinking indica-
tor light is a sign that
you need extra ventila-
tion.
K: When the FUEL indi-
cator has appeard, the
information display will
show the number of
minutes of fuel left in
the tank.
+
J: When the SAVE func-
tion is activated, the
heater will automatically
switch on or off in order
to remain within a speci-
fied temperature range.
M
Fuel filter
N
J THE CORRECT USE OF ‘SAVE’
The ‘SAVE’ function allows you to limit the temperature. When this function is activat-
ed, the heater will automatically switch off, when the room temperature exceeds the
set temperature by 3°C. Subsequently, when the room temperature has dropped again
to the set temperature, the heater will automatically switch on again.
Activate the ‘SAVE’ setting by pressing the appropriate Ƽ key. will display on the
information display (Fig. J). Switch off the function by pressing the SAVE key once again.
Without the ‘SAVE’ setting your heater will maintain the set temperature by
approximation as well, by adjusting its heating capacity. ‘SAVE’ is an economy
setting, which you can use when, for instance, you are not present in the room
or to keep it frost-free.
K THE ‘FUEL’ INDICATOR
When the FUEL indicator appears, it means that there is only fuel left for 10 more
minutes. The count-down of the remaining heating time can be seen in the infor-
mation display ¹ (Fig. K). Now you have two options:
̈ you remove the fuel tank and refill it outside the living room (section B) or
̈ you push the button EXTENSION ƾ. By pushing this button, the remaining
heating time will extend to 90 minutes. The heater will automatically switch
back to its lowest position. In the display the number 90 will appear, which
will decline to 10. At the arrival of 10, you will hear an alarm signal every two
minutes, warning you to refill the removable tank. If you do not react, the
heater will extinguish by itself. The heater will also sound a warning signal,
when it switches off. The fuel indicator will blink, while four lines (--:--)
are blinking in the information display. You can stop this by pressing the
button Ƹ once more.
Once the heater has used up all its fuel and extinguished, it will take some time,
after the refill, before the heater is completely ready for use again.
L THE ‘VENT’ INDICATOR
When there is insufficient ventilation in the room, an intermittent buzzer will
be heard (approximately once each 30 seconds) and the VENT indicator
will
be blinking. When this signal is given, ensure that the ventilation of the room is
improved (e.g. by opening a door or window a little more), to avoid that the heat-
er shuts off. When the ventilation of the room is improved, the VENT indicator and
buzzer will be deactivated. When there is still insufficient ventilation, the heater
shuts off automatically. When this occurs, e- 1 1 is displayed and the
indicator
is blinking and VENT indicator (
) is lit. After improving the ventilation of the
room (e.g. by opening a door or window a little more), the heater can be ignited
by pushing
Ƹ
again.
M MAINTENANCE
Switch off the heater and let it cool down, before you start any maintenance
work. Also disconnect the plug from the mains. Your Zibro needs hardly any main-
tenance. It is, however, important that you clean the air filter and the vent filter
with a vacuum cleaner and the grid with a damp cloth, both on a weekly
basis. Remove the air filter cap occasionally (Fig. M) and clean it with soapy water.
Prior to reinstallation, make sure that the air filter cap has fully dried.
Regularly inspect the fuel filter as well:
1
Remove the removable tank from the heater and remove the fuel filter
(Fig. N). Some drops may leak from the filter; keep a cloth at hand.
4
59
p052_061_SRE835E_uk.indd 59 28-06-12 11:22
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Zibro SRE835E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Zibro SRE835E

Zibro SRE835E Bedienungsanleitung - Deutsch - 15 seiten

Zibro SRE835E Bedienungsanleitung - Holländisch - 15 seiten

Zibro SRE835E Bedienungsanleitung - Französisch - 17 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info