6.2.3 Fixing the faceplate
Before fixing the faceplate, first read the following sections (up to page 5-20) and then return here. The preceding sections are
not needed for every installation.
When carrying out the following, make sure that the voltage is disconnected for all connection work. Both the power adapter
and the standby batteries must be disconnected.
Before fixing the faceplate, the following installation work should be complete.
Telephone and power are connected to the PCB of the base plate (section 5.3).
All connection work for additional control cables is completed on the PCB of the base plate (section 5.5).
The brightness is adjusted (section 5.4).
All jumpers are plugged in according to the desired function (section 5.7).
When all these jobs are completed, replace the faceplate and screw it tight. Proceed as follows:
Connect the flat cable of the faceplate to the base plate.
Insert the temper spring into the casing for the tamper opening and clip the faceplate from above into the
base plate.
Fold the faceplate down until it clicks audibly into the base plate.
Screw the case together from below using the screw provided.
The ABUS wireless alarm system is now ready for the following installation steps described in chapter 6.
6.3 How do I install the power and telephone connections?
The ABUS wireless alarm system is powered by a 230V AC power adapter with 9V AC. In this step, make sure only the
secondary power adapter plug is plugged into the base plate (see number 5 on page 5-14: What is what inside the
ABUS wireless
alarm system
?). The power adapter plug must never be plugged into the mains socket. The socket for the power adapter is on the
PCB in the base plate.
Alternatively, the power adapter plug can be connected directly to the base plate after the plug has been removed. The polarity is
unimportant.
For the telephone connection, you can use either an RJ45 plug or an RJ11 plug. The two analogue telephone cables a and b can
also be connected to the screw clamp as shown in the graphic. Here too, the polarity is unimportant. One or more telephone
terminal devices can be connected, but they must be connected after the
ABUS wireless alarm system. The reason: In the event
of an alarm, the system separates the connection to any series-connected telephone terminal devices and then uses this telephone
connection exclusively for transmitting the alarm message (blockade switching). In this way, you prevent a “busy” telephone from
blocking the line in the event of an alarm. To connect your telephone terminal devices to the system, see the above sketch. The
cables of your telephone line must be connected to the
Line connector of the ABUS wireless alarm system. Connect the cables of
your telephone or PBX to the
Set connector.
6.4 How do I adjust the contrast of the LCD display?
The ABUS wireless alarm system has a dimmer for adjusting the brightness and contrast of the LCD display. You should make
adjustments after plugging into the power supply and before replacing the faceplate on the base plate.
To make this setting, turn the LCD light dimmer (see number 8 on page 5-14: What is what inside the ABUS wireless alarm system?)
carefully with a small flat screwdriver until you have set the right brightness.
9 V AC connector
RJ31
Line/Set
RJ11
Line/Set
Screw
terminal
a/b Set
Screw
terminal
Line
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Abus FU9000 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Abus FU9000

Abus FU9000 Installationsanweisung - Deutsch - 96 seiten

Abus FU9000 Bedienungsanleitung - Deutsch - 55 seiten

Abus FU9000 Bedienungsanleitung - Englisch - 56 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info