12V
0V Dip switch 8 must be set
to OFF.
Program the behaviour of this siren in the wireless alarm
system under the following points:
Partitions for acknowledge functions
Editing WAM for alarm functions
3. Connecting a conventional siren
If the accessory module is used in function 4 (wireless siren
module) and a conventional siren should be used without its own
power supply, connect the accessory module with the siren
as follows:
Please note that the
maximum load capacity
per relay may not exceed
500 mA.
Remove all jumpers when
using this connection.
Dip switch 8 must be
set to ON.
12V
0V
6.3.5 Wireless siren transmitter/receiver
Function 5 / LED 5
When used as a wireless siren transmitter or receiver, a wireless
siren can be connected to any centre over the accessory module.
The inputs of the accessory module are connected to the alarm
centre relay outputs used for triggering the flash and siren. The
outputs of the accessory module are connected to the tamper input
of the alarm centre. A further accessory module is connected to
any signalling device. The flash and siren can be triggered wirelessly
and independently of each other.
To use the accessory modules as wireless siren
transmitters/receivers, proceed as follows:
Firstly, program the accessory module connected to a siren as a