Guidance and Manufacturer’s Declara on
The AV400, CC300, and HF470 are intended for use in the electromagnetic environment
speci ed below. The customer or the user of the AV400, CC300, or HF470 should assure that
it is used in such an environment.
IMMUNITY Test IEC 60601
Test Level
Compliance Level Electromagne c environment -
guidance
Electrosta c
Discharge (ESD) IEC
61000-4-2
±6 kV contact
±8 kV air
±6 kV contact
±8 kV air
Floors should be wood, concrete,
or ceramic  le. If fl oors are covered
with synthe c material, the rela ve
humidity should be at least 30%.
Electrical fast
transient/burst
EC 61000-4-4
± 2 kV for power
supply lines
± 1 kV input/output
lines
± 2 kV for power
supply lines
Not applicable
Mains power quality shouldbe that
of a typical commercial or hospital
environment
Surge
IEC 61000-4-5
± 1 kV line(s) to
line(s)
± 2 kV line(s) to
earth
± 1 kV di eren al
mode
± 2 kV common
mode
Mains power quality shouldbe that
of a typical commercial or hospital
environment
Voltage dips, short
interrup ons and
voltage varia ons on
power supply input
lines
IEC 61000-4-11
<5 % UT
(>95 % dip in UT) for
0.5 cycles
40 % UT
(60 % dip in UT) for
5 cycles
70 % UT
(30 % dip in UT) for
25 cycles
<5 % UT
(>95 % dip in UT)
for 5 s
<5 % UT
(>95 % dip in UT)
for 0.5 cycles
40 % UT
(60 % dip in UT) for
5 cycles
70 % UT
(30 % dip in UT) for
25 cycles
<5 % UT
(>95 % dip in UT)
for 5 s
Mains power quality should be
that of a typical commerial or
hospital environment. If the user
of the AV400 requires con nued
opera on during power mains
interrup ons, it is recomended
that the AV400 be powered from
an uninterrup ble power suply or
a ba ery
Power frequency
(50/60 Hz) magne c
e l d
IEC 61000-4-8
3 A/m 3 A/m Power frequency magne c
elds should be at levels
characteris c of a typical loca on
in a typical commercial or hospital
environment.
NOTE: UT is the AC mains voltage prior to applica on of the test level.
Guidance and Manufacturer’s Declara on – Electromagne c Immunity
The AV400, CC300, and HF470 are intended for use in the electromagnetic environment
speci ed below. The customer or the user of the AV40 0, CC300, or HF470 should assure that it
is used in such an environment.
IMMUNITY TEST IEC 60601 TEST
LEVEL
COMPLIANCE
LEVEL
Electromagne c Environment –
Guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC 61000-4-3
3 Vrms
150 kHz to 80 MHz
3 V/m
80 MHz to 2.5 GHz
3 Vrms
3 Vrms
Portable and mobile RF communica ons
equipment should be used no closer to
any part of the AV400, including cables,
than the recommended separa on
distance calculated from the equa on
applicable to the frequency of the
transmi er.
Recommended separa on distance
d = 1,2
P
d = 1.2
P 80 MHz to 800 MHz
d = 2.3
P 800 MHz to 2.5 GHz
where P is the maximum output
power ra ng of the transmi er in
wa s (W) according to the transmi er
manufacturer and d is the recommended
separa on distance in meters (m). Field
strengths from fi xed RF transmi ers,
as determined by an electromagne c
site survey, should be less than the
compliance level in each frequency
range.
Interference may occur in the vicinity of
equipment marked with the following
symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situa ons. Electromagne c propaga on is aff ected by
absorp on and refl ec on from structures, objects, and people.
Field strengths from fi xed transmi ers, such as base sta ons for radio (cellular/cordless) telephones
and land mobile radios amateur radio, AM and FM radio broadcast and TV broadcast cannot be
predicted theore cally with accuracy. To assess the electromagne c environment due to fi xed RF
transmi ers, an electromagne c site survey should be considered. If the measured fi eld strength in
the loca on in which the AV400 is used exceeds the applicable RF compliance level above the AV400
should be observed to verify normal opera on. If abnormal performance is observed, addi onal
measures may be necessary, such as re-orien ng or reloca ng the AV400. Over the frequency range
150 kHz to 80 MHz, fi eld strengths should be less than 3 V/m.
Guidance and Manufacturer’s Declara on - Electromagne c Emissions
The AV400, CC300, and HF470 are intended for use in the electromagnetic environment
speci ed below. The customer or the user of the AV400, CC300, or HF470 should assure
that it is used in such an environment.
Emissions test Compliance Electromagne c Environment Guidance
RF Emissions
CISPR 11
Group 1 The AV400 uses RF energy only for its internal
func on. Therefore, its RF emissions are very
low and not likely to cause any interference in
nearby electronics
RF Emissions
CISPR 11
Class A The AV400 is suitable for use in all
establishments other than domes c and those
directly connected to the public low-voltage
power supply network that supplies buildings
used for domes c purposes
Harmonic Emissions
IEC 6100-3-2
Complies
Voltage Fluctua ons
IEC 6100-3-3
Complies
Recommended separa on distances between
portable and mobile RF communica ons equipment and the AV400
The AV400, CC300, and HF470 are intended for use in an electromagnetic environment in which
radiated RF disturbances are controlled. The customer or the user of the AV400, CC300, or HF470
can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the AV400 as recommended
below, according to the maximum output power of the communications equipment.
Rated Maximum
Output
power of transmi er
W
Separa on distance according to frequency of transmi er
m
150 kHz to 80 MHz
d = 1.2
P
80 MHz to 800 MHz
d = 1.2
P
800 MHz to 2.5 GHz
d = 2.3
P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
11.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmi ers rated at a maximum output power not listed above, the recommended separa on
distance d in meters (m) can be es mated using the equa on applicable to the frequency of the
transmi er, where P is the maximum output power ra ng of the transmi er in wa s (W) according to
the transmi er manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separa on distance for the higher
frequency range applies. NOTE 2 These guidelines may not apply in all situa ons. Electromagne c
propaga on is aff ected by absorp on and re ec on from structures, objects, and people.
產品規
17
Production 1P after translator
ACU0004961_TRAD_CHINESE.indd May 15, 2017 3:03 PM right page keith@type ownyc.com
917.370.8219
、清
消毒
使 A V 4 0 0,並
AV400進行而保使
淨。
刮痕或污使
AV400 AV400退
AccuVein修。
取得AV400表面和
持清 使酒精
70% 的污
顯示影。
AV400電機使含70%
10%混合
濕拭 使劑與
布。
AV400AV400AV400
體內AV400
熱或高AV400
毒。
在充AV400或
下後AV400
拔下機
排除
AV400測到法正
螢幕使螢幕
顯示 AV400
關閉
境過4°C/3F33°C/90°F
會出現 出現使
AV400即可
其他明電
現故
應立即停使AV400
+1 ( 8 1 6 ) 9 9 7- 9 4 0 0, 3 A c c u Ve i n
絡。
質保
AccuVein授權購買
AV400AccuVein銷商或理人
購買AV400與工
固期
90AccuVein
免費期限滿
件的任 AccuVein
取得退回RMA
裝置期起90保固 +1
( 8 1 6 ) 9 9 7- 9 4 0 0, 3,與 A c c u V e i n
求維步資
蓋任或虐
AccuVein或其外的
AccuVein面保
何其他明
AccuVein保固 保固
絡AccuVein
www.accuvein.com/legal/warranty
AccuVein或客方可
的任間接
向對方負
此等署協議
因對此等協議約或使
被告解此
賠,
包括合約
形式
質保
16
Production 1P after translator
ACU0004961_TRAD_CHINESE.indd May 15, 2017 3:03 PM left page
keith@type ownyc.com
917.370.8219
239
keith@typeownyc.com 917.370.8219
ACU0004739D April 5, 2017 5:17 PM left page
keith@typeownyc.com 917.370.8219
ACU0004739D April 5, 2017 5:17 PM right page
ACU0004739D.indd 239 5/15/17 3:03 PM
241

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für AccuVein AV400 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info