677361
38
Zoom out
Zoom in
Vorherige Seite
1/118
Nächste Seite
38
EN
Scale can be removed from the interior part of the tank manually, through the fitting opening. It is
rationale to flush the tank with water ray after scale removal.
8.5. Prevention of frost damages
If temperature may fall below the freezing point in the location of the hot water tank, the heating of the
tank must not be switched off or the tank must be discharged in periods of frost danger.
8.6. In case of indirect heating
OVERHEATING PROTECTION MUST BE PERFORMED BY THE INDIRECT HEATING
EQUIPMENT!
8.7. Air filter
Clean the air duct every month as this influences heating performance! If the filter has
been mounted directly into air inlet (i.e. air inlet is not connected to air duct), dismounting and cleaning of the
filter can be performed in the following way: the air inlet closing ring has to be turned counter-clockwise, the
filter must be removed and perfectly cleaned and then it must be put back to its place.
8.8. Shutdowns not caused by errors
a) 3-minutes protection
When the appliance is under power, one must wait 3 minutes to protect the compressor at immediate
start-up after shutdown.
b) If the appliance launches a self-protection mechanism and then shuts down, please check the
following:
When the power indicator lights up, it may happen that the appliance does not fulfil all the conditions for
system start up when being switched on. One should also check that air inlet or air outlet are not blocked or no
strong draught reaches the air outlet.
c) Defreezing
The evaporator may freeze in a wet and cold environment, so it can reduce water heating performance. This
time, the appliance is set to stop water heating, changes to defreezing and starts water heating only then.
During defreezing, the fan stops, the four-direction valve turns the way of flow and the compressor is
operating continuously.
Defreezing may range from 3 minutes to 10 minutes, depending on the external environment and the frost.
d) Temperature display
When the appliance stops, temperature decrease due to heat release is quite normal. The system is started
automatically after falling back to a certain heat degree.
During water heating, the indicated water temperature may decrease for a while or it can not increase due to
heat exchange of the water. When the tank has fully reached the pre-set temperature, the appliance stops
automatically.
8.9 Errors and solutions
Malfunctioning
Reason
Solutions
The outlet water is
cold. The display is
dark.
Check whether power supply exists
Outlet water is set an a low temperature;
Outlet water temperature
controller is damaged; Circuit board of
indicating indicator is damaged;
Set outlet water at a higher
temperature;
Contact the technician.
No hot water from the
outlet.
Tap water has been cut away;
Water pressure is too low; Inlet valve has
been closed.
It will return to normal after water
supplied; Use it when the pressure is
higher; Open the inlet water valve.
Water leakage
The joints on the pipeline are
not sealed well.
Check and reseal all the joints.
8.10 Self-protective mechanisms of the appliance
a) In case of self-protection, the appliance shuts down, starts auto-check and re-starts when the
defensive mechanisms are put into operation.
38

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für ACV HP300 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info