800043
4
Zoom out
Zoom in
Vorherige Seite
1/92
Nächste Seite
4
r tank lock (13) and pull out a little the water tank (8) from the back of the device. Use the jug to pour clear, cold water, be careful not to
exceed the maximum level. You can pour water w/o pulling out the water tank completely. To remove water tank completely, first remove
the pump (11) by releasing thw two black brackets (15) and pull out the water tank (8). After water pouring, turn the water tank lock (13)
to horizontal position. Do not tilt the device after pouring the water to water tank. Do not remove water tank while the device is plug in
power supply.
3. Connect the plug to power supply, the device is in standby mode. The LCD display showing ambient room temperature is illuminated.
Now can be used control panel (2) or remote control (14) to operate the device (figure B).
15. Brackets
Turn on the device using the power button (A). The device starts working in middle speed. Press the button (A) again to switch it back to
standby mode.
B – speed button
1. Place the unit on a dry, flat surface.
4. The button (B) allows you to change the speed of the fan. The following speeds can be selected: fast, medium and slow. The
USING THE DEVICE
PRODUCT DESCRIPTION – TOWER AIR COOLER AD7855 – picture A
3. Air outlet 4. Base
Step 2: Align the four bolt holes of the assembled base (4) with the hull bolt posts and lock the fuselage and base with the 4 self-tapping
screws (Figure C2). At the same time, lock the two screws securing the base and place the product in the right direction.
7. Cover with net 8. Water tank
9. Power cord 10. Water level indicator
11. Pump 12. Plastic containers
13. Water tank lock 14. Remote control
A noticeable reduction in the temperature of the outlet air occurs after putting into the water tank (8) the plastic containers (12) attached
to the product. The plastic containers should be previously frozen in the freezer for few hours. It is recommended to fill the plastic
container (12) with cold tap water and do not exceed MAX level marked on the plastic container. The content of plastic container is
prohibited to edible. Keep away from children.
Remote control & Control panel – picture B
C – oscillation button
D – mode button
E – timer button F - wet cooling button
2. Rotate to flat position the watedrain
Step 1: First, insert the base's latch into the square hole (Figure C1).
5. Filter 6. Screw
1. Handle 2. Control panel
A – power button
• WARNING: When the water is not replaced and the tank is not properly cleaned every 3 days, microorganisms that may be present in
the water or in the environment where the device is used or stored may develop in the water tank and be blown out to the
surroundings. This can cause a very serious health risk.
DESCALING
4. Never leave water in the tank when the device is not in use.
1.Perform the descaling procedure in accordance with the instructions of the descaling agent specified by the manufacturer.
2.Use descaling agents intended for this purpose.
4. Descaling only the water tank with the device turned off
2. Do not get wet the device or wet the area around the device. If moisture appears, reduce the efficiency of the humidifying function.
3. Carry out the descaling procedure at least every 3 months.
21. Do not place any objects on the device.
BEFORE FIRST USE
3. Do not allow absorbent materials such as carpets, curtains, tablecloths to get wet.
22. The device can be used only with properly working ventilation.
23. To provide additional protection, it is advisable to install a residual current device (RCD)
in the electric circuit with a rated residual current not exceeding 30mA. Ask an
electrician for this.
ASSEMBLY
Before first use
1. It should be remembered that a high level of humidity may favor the development of biological organisms in the environment.
• WARNING: Every three days, empty the water tank and top up with clean water. Before refilling, clean the tank with fresh tap water or
using detergents. Remove any scale, deposits or film that has formed on the sides of the tank and on the interior surfaces. After
washing, wipe all surfaces dry.
Take the device out of the packaging. Assemble the base (4) in 2 steps (picture C):
5. During filling and cleaning, disconnect the device from the mains.
6. Clean the device and water tank before using it again.
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Adler AD 7855 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info