A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
DECOMPRESSION
Decompression mode activates when theoretical No Decompression time and depth limits are exceeded.
Upon entry into Deco, the Audible will sound during which the alarm LED and full TLBG will flash. Two Up Arrows will also flash
(Fig. 46), until within 10 FT (3 M) of and below the required Stop Depth (the Stop Zone).
• S (< 2 sec) to silence the Audible.
> Once within 10 FT (3 M) of and below the required Stop Depth (in the Stop Zone), the full Stop icon (smaller Up and Down
Arrows with Stop Bar) will be displayed solid.
Managing Deco Stops
To fulfill your decompression obligation, you should make a safe controlled Ascent to a depth slightly deeper than, or equal to,
the required Stop Depth indicated and decompress for the Stop Time indicated.
The amount of decompression credit time that you receive is dependent on Depth, with slightly less credit given the deeper you
are below the Stop Depth indicated.
You should stay slightly deeper than the required Stop Depth indicated until the next shallower Stop Depth appears. Then, you
can slowly ascend to, but not shallower than that indicated Stop Depth.
DECO STOP MAIN, information includes (Fig. 47) -
> Current Depth with FT (or M) icon.
> Nx, (PZ+), CF icons - if they apply.
> Graphic DECO STOP with Stop icon (arrows and bar).
> Stop Depth with graphic FT (or M) and Stop Time (up to 199 min) with graphic MIN.
> Pressure with PSI (or BAR) icon, when using Gas 1; or graphic SPG if 2, 3, or 4.
> Graphic GAS1 (or 2, 3, 4), one in use.
> ATR (up to 199 min) with icons, when using Gas 1; dashes if Gas 2, 3, or 4.
> Full TLBG.
> VARI, if ascending.
A (< 2 sec) to access ALTs.
M (2 sec) to access Gas Switching*.
S (< 2 sec) to activate Backlight and acknowledge alarms.
S (2 sec) to access Compass*.
*These items can only be accessed while viewing the Main.
DECO STOP ALT 1, information includes (Fig. 48) -
> Graphic ALt.
> Time of Day (hr:min) with graphic A (or P) if 12 Hour.
> Temperature with ° icon and graphic F (or C).
A (< 2 sec) to access ALT 2.
Revert to Main in 5 sec, if A is not pressed.
DECO STOP ALT 2, information includes (Fig. 49) -
> Graphic ALt.
> Max Depth with graphic FT (or M) MAX.
> EDT (min) with graphic.
> Total Ascent Time with TAT and min icons, displays 199 when => 199 min.
A (< 2 sec) to access ALT 3 if Nx, or revert to Main if Air.
Revert to Main in 5 sec, if A is not pressed.
DECO STOP ALT 3, information includes (Fig. 50) -
> Graphic ALt with Nx icon.
> %O2 accumulated with graphic O2SAT.
> PO2 value (x.xx ATA) with icon.
> Graphic GAS 1 (or 2, 3, 4), one in use.
> FO2 with icon, value set for Gas in use.
5 sec or A (< 2 sec), revert to Main.
Fig. 46 - DECO ENTRY
Fig. 47 - DECO STOP MAIN
Fig. 48 - DECO STOP ALT 1
Fig. 50 - DECO STOP ALT 3
Fig. 49 - DECO STOP ALT 2
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 AI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info