A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
VIOLATION GAUGE MODE (VGM)
If a Deco Stop Depth greater than 70 FT (21 M) is required, operation will enter VGM. This would be preceded by DV2.
Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing.
VGM turns the A300 AI into a digital instrument without any decompression or oxygen related calculations or displays.
Upon activation of VGM, the Audible will sound during which the alarm LED and full TLBG* will flash. The graphic VIOLATION
and (2) Up Arrows will also be displayed flashing, in place of Deco data (Fig. 55), until on the surface.
*After the audible is silenced, the TLBG will be removed.
VGM Main, information includes (Fig. 56) -
> Current Depth with FT (or M) icon.
> (2) Up Arrows with graphic VIOLATION, flashing until on surface.
> Pressure with PSI (or BAR) icon, if Gas 1; or graphic SPG when Gas 2 (3, 4).
> Graphic GAS1 (or 2, 3, 4), one in use.
> ATR (up to 199 min) with icons, if Gas 1; or dashes ( - - ) when Gas 2 (3, 4).
> VARI, while ascending.
A (< 2 sec) to access ALTs.
S (< 2 sec) to activate Backlight or acknowledge alarms.
S (2 sec) to access Compass*.
*This item can only be accessed while viewing the Main.
VGM ALTs, information is similar to Deco ALTs.
VGM ON SURFACE
The graphic VIOLATION flashes for the first 10 minutes (Fig. 57), then VIOL alternates with NORM (Fig. 58), each On 3 seconds,
until unit shut down after 24 hours with no dives*.
*A full 24 hour surface interval must then be served before all functions are restored.
During that 24 hours, access to all menus and screens is available except those associated with Ni-O2 calculations such as
Desat, Plan, Set FO2. The Fly countdown timer provides the time remaining (of the 24 hours required) before normal opera-
tion can resume with full features and functions.
HIGH PO2
Warning >> at 0.80 to 1.40 (0.20 less than Alarm value set).
Alarm >> at Set Point value, except in Deco then at 1.60 only.
When partial pressure of oxygen (PO2) increases to the Warning level; the Audible will sound during which an Up Arrow and
the PO2 value with icon will flash in place of Pressure (Fig. 59).
> After the Audible is silenced, Pressure is restored, and the Up Arrow remains on solid until PO2 decreases below the
warning level.
If PO2 continues to increase and reaches the PO2 Alarm level, the Audible will sound again during which (2) Up Arrows and the
PO2 value with icon will flash in place of Pressure (Fig. 60).
> After the Audible is silenced, Pressure is restored, and the Up Arrows remain on solid until PO2 decreases below the alarm
level, at which time one of the Up Arrows is removed.
A (< 2 sec) to access ALTs, similar to No Deco.
M (2 sec) to access Gas Switching*.
S (< 2 sec) to activate Backlight and acknowledge alarms.
S (2 sec) to access Compass*.
*These items can only be accessed while viewing the Main.
PO2 during Deco
The PO2 alarms that were set do not apply when in Deco.
When PO2 reaches 1.60, the Audible will sound during which the PO2 value with icon will flash in place of Pressure (Fig. 61).
> After the Audible is silenced, the PO2 value with icon will alternate with Pressure once each minute*.
*PO2 will be displayed for 10 seconds, then Pressure will be displayed for 50 seconds once each minute until PO2
decreases below 1.60, then PO2 will not be displayed.
Fig. 55 - VGM MAIN
(during Audible)
Fig. 57 - VGM MAIN
(on surface < 10 min)
Fig. 56 - VGM MAIN
(after Audible)
Fig. 59 - PO2 WARNING
(during Audible)
Fig. 60 - PO2 ALARM
(during Audible)
(1) Up Arrow is Warning.
(2) Up Arrows is Alarm.
Fig. 61 - PO2 ALARM
(during Audible in Deco)
Fig. 58 - VGM MAIN
(on surface > 10 min)
alternate
with
NORM
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 AI wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info