A300 CS OPERATING MANUAL
© 2002 Design, 2014 Doc. No. 12-7287-r04 (8/21/14)
BRIGHTNESS CONTROL
The level (%) of screen Brightness can be adjusted by accessing the Brightness Adjustment screen while viewing the Home Menu
screen, or a Surface or Dive Main screen (NORM, GAUG, or FREE), or the Compass OP Main screen.
A (2 sec), while on the surface or during dives, will access a Brightness adjustment screen with the last % highlighted and
flashing. During a Low Battery Warning or Alarm condition, the level will be limited to 60% maximum.
ADJUST BRIGHTNESS, information is to include (Fig. 10):
> xx % (last value saved), flashing.
S (2 sec) to step back to the screen from which access was gained without changing the % value.
A (< 2 sec) to step upward through values of 10% to 100% one at a time in increments of 10%.
M (< 2 sec) to step down through values one at a time.
S (< 2 sec) to save the % setting and revert to the screen from which access was gained.
TIP: When an adjustment is made during a dive that is lower than the Auto Dim % set prior to the dive, the screen will remain
illuminated at the level you save until you adjust it to a % level above the Auto Dim % set.
AUDIBLE ALARM
While operating in NORM or GAUG Mode, the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it
is set Off. During that time, the Audible can be acknowledged and silenced by pressing S (< 2 sec).
The Audible will not be active when it is set OFF (a Set Alarms Menu selection).
FREE Dive Mode alarms, which emit 3 short beeps either 1 or 3 times, cannot be acknowledged or set OFF.
Alarms that strike during operations in Compass Mode are described on page 45.
Situations that will activate the NORM/GAUG 10 second Alarm include -
** Items apply only in NORM mode.
• Air Time Remaining (ATR) at 5 minutes, then again at 0 minutes.
• Turn Pressure at the value set (Transmitter 1 only).
• End Pressure at the value set (active Transmitter).
• Descent deeper than the Depth Alarm value set.
• Dive Time Remaining at the value set**.
• Elapsed Dive Time at the value set.
• PO2 level at .20 < value set for the gas in use and again at the value set**.
• O2 accumulation at 240 OTU (80%), then again at 300 OTU (100%)**.
• TLBG at the value set**.
• Ascent Rate (alarm = all 5 segments) exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at
60 FT (18 M) and shallower.
• Loss of the active Transmitter Link signal for more than 15 seconds during a dive.
• Entry into Decompression (Deco)**.
• Conditional Violation (above a required Deco Stop Depth < 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth => 5 minutes)**.
• Delayed Violation (a Deco Stop Depth > 60 FT/18 M is required)**.
• Delayed Violation (Depth > 330 FT/100 M).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA for that gas**.
A single short beep (which cannot be disabled) sounds when -
• 5 minutes elapse on the surface after the Violation dive.
3 short beeps (which cannot be disabled) sound when -
• Ascent Rate (warning = 4 segments) is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM
(7.5 to 9 MPM) at 60 FT (18 M) and shallower.
• FREE Dive Repeating Time Interval Alarm - 3 beeps once every 30 seconds, if set On.
• FREE Dive Depth Alarms 1, 2, 3 - 3 beeps 3 times at each value set.
• FREE Dive TLBG Alarm (Caution zone, 7 segments) - 3 beeps 3 times.
• FREE Dive Violation - 3 beeps 3 times upon entry into Decompression.
• FREE Countdown Timer - 3 beeps 3 times when time counts down to 0:00.
During the following situations, the audible will not turn off when acknowledged -
• Delayed Violations 1, 2, 3.
• Deco Stop Depth Violation => 70 FT/21 M stop required.
• FREE mode alarms.
20%
ADJUST BRIGHTNESS
Fig. 10 - BRIGHTNESS
ADJUSTMENT
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aeris A300 CS wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info