3
Fig. 2.1Outline of the LCD
No. Name Description
1 Fan speed Displays the fan speed of the indoor unit: high, medium, low and auto.
2 Operating mode Displays the operating mode of the indoor unit: auto, cool, dry, fan and
heat.
3 System clock Displays the weekday and current time (hour and minute) based on a
24-hour time system.
4 Shield Displays the shielded status, “ALL”, “TEMP”, “MODE” and “ON/
OFF”.
5 Weekly timer Displays the timing period (unit: 0.5 hour) which will cycle each week.
6 Set temperature/Indoor
unit code
Displays the set temperature, indoor unit code (01-16), and the Celsius
or Fahrenheit scale symbols.
7 Control mode Displays “CENTER” under the centralized control mode and no display
under the single control mode.
8 Ambient temperature/
Serial port
Displays the ambient temperature, serial port and the Celsius or
Fahrenheit scale symbols.
9 Indoor unit code/ on/off
status
The indoor unit codes are indicated by numbers which will be displayed
when the corresponding indoor unit is online. “ ” is the indoor unit on/
off status indicator. The unit is “On” when the indicator is lit; the unit is
“Off” when the indicator is not lit.
10 Error , Child lock Displays the error codes when error(s) arise(s) and also “CHILD
LOCK” when this function is activated.
Port 4 (Duct Type)
Port 1 (9RF)
Vired Controller
Port 2 (9RF)
Port 3 (9RF)
Vired Controller Vired Controller
Duct Type
Duct Type
Duct Type
Max.16
Max.16
Max.16
Max.16
Communication Module
Communication Module
Communication Module
Max.16
o
&HQWUDO:LUHG Controller
(Max. 16 indoor units)
PC & Long-Distance Monitoring System
Centralized controller
Fig. 2.2 Introduction to Symbols on the LCD
Table 2.1 Introduction to the Symbols on the LCD
Fig.1.2 Connection of the &HQWUDO:LUHG Controller and the Long-distance Monitoring System/Centralized
Controller
Notes:
c. Only the multi VRF units can be integrated with the long-distance monitoring system/centralized
controller.
d If the shielding function has been set neither for the &HQWUDO:LUHG controller nor for the long-distance
monitoring system/the centralized controller, the &HQWUDO:LUHG controller will be fully compatible with the
long-distance monitoring system/the centralized controller. The &HQWUDO:LUHGs control will be inferior to that
of the latters control.
e When the shielding function has been set for both the FHQWUDOZLUHG controller and the long-distance
monitoring system/the centralized controller, the &HQWUDO:LUHG controller can only be used to view the status of
the unit; its control function will be rendered ineffective.
2. LCD
2.1 Outline of the LCD
Note: the FHQWUDOZLUHG controller can connect with a maximum of three sets of multi VRF units and multiple
duct type units, however, the total of the indoor units of all four ports may not exceed 16.
1.2.2 Integration of the &HQWUDO:LUHG Controller and Long-distance Monitoring System/
Centralized Controller.
2.2 Introduction to Symbols on the LCD
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
FriS at Sun
24 68 10 12 14 16 18 20 22 24



9
10
1112
1314
1516
CENTER
SUNMON TUEW ED THUF RI SAT
AUTO
SUN
MON
TUE
WED
THU
FRISAT
SHIELD
CHLD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
AllonAlloff
Fan
AllonAlloff
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
FriS at Sun
24 68 10 12 14 16 18 20 22 24



9
10
1112
1314
1516
CENTER
SUNMON TUEW ED THUF RI SAT
AUTO
SUN
MON
TUE
WED
THU
FRISAT
SHIELD
CHLD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
AllonAlloff
Fan
AllonAlloff
&(175$/:,5('&21752/&(175$/:,5('&21752/
4

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Airwell RCW4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info