638709
6
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
6
7
2 4 6 8 10 12 14 16 18 20 22 24



9
10
11 12
13 14
15 16
CENTER
SUN MON TUE WED THU FRI SAT
AUTO
SUN
MON
TUE
WED
THU
FRI SAT
SHIELD
CH LD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
All
onAll
off
2 4 6 8 10 12 14 16 18 20 22 24



9
10
11 12
13 14
15 16
CENTER
SUN MON TUE WED THU FRI SAT
AUTO
SUN
MON
TUE
WED
THU
FRI SAT
SHIELD
CH LD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
All
onAll
off
CENTER
THU
THU
ROOM
ROOM
SET
SET
All
onAll
off
All
onAll
off
5. Operating Status View of the Indoor Unit and Control Mode
5.1 Operating Status View of the Indoor Unit
It can be generally seen on the LCD that the minimum code of the online indoor unit flashes, with its
operating status, set temperature, and shield status etc., displayed. The minimum code can be replaced by
other indoor units by pressing the corresponding indoor unit code button (If the requested indoor unit is
offline, then the operation will be rendered null and void, displaying "NO".).
See Fig.5.1 for operating status viewing instructions of the indoor unit:
The default status of the indoor unit is
the one with minimum code.
Press “2/10” to select unit 2.
Press “2/10” again to select unit 10.
Confirm/Cancel
Mode
Fan
On/Off
Timer/Time Central
Shield
Mon
Tue
Wed Thu
Fri Sat Sun
2 4 6 8 10 12 14 16 18 20 22 24



9
10
11 12
13 14
15 16
CENTER
SUN MON TUE WED THU FRI SAT
AUTO
SUN
MON
TUE
WED
THU
FRI SAT
SHIELD
CH LD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
All
onAll
off
Confirm/Cancel
Mode
Fan
On/Off
2 4 6 8 10 12 14 16 18 20 22 24



9
10
11 12
13 14
15 16
CENTER
SUN MON TUE WED THU FRI SAT
AUTO
SUN
MON
TUE
WED
THU
FRI SAT
SHIELD
CH LD LOCKI
ERROR
ROOM
COM
SET
INNER UNIT
TEMP
MODE
ON/OFF
ALL
All
onAll
off
Confirm/Cancel
Confirm/Cancel
Mode
Mode
Fan
Fan
On/Off
On/Off
Timer/Time
Central
Shield
Mon
Tue
Wed Thu
Fri Sat Sun
10
10
THU
THU
ROOM
ROOM
SET
SET
All
onAll
off
All
onAll
off
Press the indoor unit code to select the
corresponding unit.
( to adjust the temperature.
The default status of the indoor unit is
the one with minimum code.
Press “Central” to go to the centralized
control mode.
Fourteen seconds (thirty seconds for the duct type unit) after the control command is sent out, the set
parameters of the indoor unit will be displayed.
See Fig. 5.2 for temperature control instructions under single control:
Fig. 5.2 Temperature Control under Single Control
For other settings, please refer to subsequent sections.
5.2.2 Centralized Control
Press Central to go to the centralized control mode. The LCD will display CENTER.
Set the operating status of the indoor unit and send out control commands, including On/Off, Mode, Fan,

will be sent out to all online indoor units.
Thirty seconds after the control command is sent out or if Central is pressed, CENTER will disappear
from the LCD and the unit will revert back to the single control mode with the set parameters of the
current indoor unit displayed.
See Fig.5.3 for instructions on entering the centralized control mode:
Fig. 5.3 Entering Centralized Control Mode
Fig.5.1 Operating Status View of the Indoor Unit
5.2 Control Mode
5.2.1 Single Control
Select the required indoor unit using the indoor unit code button. That particular code will flash on the LCD.
Set the operating status of the indoor unit and send out control commands, including On/Off, Mode, Fan,

will be sent out.
&(175$/:,5('&21752/&(175$/:,5('&21752/
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Airwell RCW4 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info