601640
17
Zoom out
Zoom in
Vorherige Seite
1/224
Nächste Seite
Assembly
467 777_a 17
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
2
. Cable drums should always be unrolled
completely.
Damaged or brittle extension cables must not
be used.
Check the condition of your extension
cable each time you start to use the
equipment.
ASSEMBLY
Erecting the equipment
1. Prepare a flat and solid erection site.
2. Erect the machine horizontally and protected
against flooding.
3. Bolt the house water system securely at the
bolting points (Fig. A -7) if necessary.
4. The house water system must be protected
from rain and direct water jets.
ADVICE
In daily operation (automatic mode), you
must ensure, by suitable measures, that,
in the event of a fault in the equipment,
consequential damage caused by floo-
ding is excluded.
Connecting the suction line
1. Select the length of the suction line (Fig. B
-17) to make sure that the house water sys-
tem cannot run dry. The suction line must al-
ways be at least 30 cm under the surface of
the water.
2. Connect the suction line. Make sure that the
connection is tight, but do not damage the
thread.
We recommend using flexible lines at the
pump inlet (Fig. A -10). This ensures that
pressure or tension on the house water
system cannot be exerted.
3. If the water has a small amount of sand in it,
a pre-filter must be fitted between the suction
line and the pump inlet. Ask your expert dea-
ler about this.
4. Always lay the suction line with an upward
gradient.
ADVICE
If the suction height is more than 4m, you
must use a suction hose having a diame-
ter greater than 1". We recommend the
use of an AL-KO suction unit with suction
hose, suction filter and flow-back stop.
Ask your expert dealer.
Fitting the pressure line
1. Screw the connecting nipple (Fig. B -15) with
the round seal ring (Fig. B -16) into the pump
outlet (Fig. A -4).
2. Screw the elbow nipple (Fig. B -13) with seal
(Fig. B -14) onto the connecting nipple (Fig. B
-15) and turn the elbow nipple in the desired
direction.
3. Fix a pressure line (Fig. B -11) onto the elbow
nipple (Fig. B -13).
4. Open all the closing off devices (valves, spray
nozzles, water cock) in the pressure line.
STARTUP
ADVICE
On initial commissioning the display
shows (Fig. E -29) all information in
English. Select the desired language
with the MODE button (-30) and confirm
with the SET button (-31) . The air pres-
sure in the storage vessel can now be
checked.
Check the air pressure in the storage vessel
CAUTION!
Operation is not possible under an air
pressure of 1.4 and over 1.9 bar. The
pump does not start.
1. Unplug the mains plug on the pump.
2. Slide the closing off cover valve (Fig. D -27)
on the back of the storage vessel (Fig. A -6)
upwards.
3. Check the air pressure at the valve (Fig. D
-28) with an air pump or a tyre filler, each ha-
ving a pressure indicator.
4. Then close the closing off cover valve on the
back of the storage vessel again.
5. Replace the mains plug.
The house water system can now be
commissioned.
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

al-ko-6000-fms-premium

Suche zurücksetzen

  • Mein Alko 6000 FMS premium schaltet sich immer aus. ( der druck fällt ab ) !
    Was kann ich machen ? Eingereicht am 19-3-2020 09:34

    Antworten Frage melden
  • Kann ich bei dem HW ALKO 6000 den Abschaltdruck von 4 atü auf zB.5 atü und den Einschaltdruck von 2 atü auf zB. 3 atü erhöhen Eingereicht am 28-7-2017 16:08

    Antworten Frage melden
  • bei meinem alko 6000 fms premium befindet sich luft im gerät sodass nur wenig bzw unregelmässig druck aufgebaut wird Eingereicht am 19-6-2017 21:48

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Al-ko 6000 FMS premium wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info