Startup
18 HWA 5000/6000 FMS Premium
Filling the house water system
CAUTION!
Before commissioning, the house water
system must always be filled up to the
overflow with water, so that it can draw
water immediately. If the pump runs dry
it will be destroyed.
ADVICE
Fill the suction hose with water before
screwing in place to reduce the suction
time.
1. Open the filling screw (Fig. A -3) with the filter
key (Fig. C -19/A).
2. Fill with water via the filling screw until the
pump housing (Fig. A -2) is full.
3. Screw the filling screw in.
Switching the pump on
1. If necessary, in the pressure line (Fig. B -11)
open one of the existing closing off devices
(valve, spray nozzle, water cock).
2. Insert the mains plug on the connection cable
into the plug socket.
The pumps starts to feed.
3. When no more air comes out with the water,
close the closing off device in the pressure
line.
The pump switches off automatically af-
ter the switch-off pressure has been re-
ached.
The house water system is ready for ope-
ration.
When switching on via the pressure
switch the display shows NORMAL X
and PRESSURE together with the actual
pressure.
Initial commissioning
Only on initial commissioning, the display shows
NORMAL X and PRESSURE.
ADVICE
If no water is drawn up via the suction
line (Fig. B -17) in approx. 90 seconds,
the dry running protection switches off
the pump, and the display shows ALARM
and SUCTION SIDE. Check the suction
line, the clear sight cover (Fig. A -1) and
all the screwed fittings for leaks, press
the RESET button and carry out the in-
itial commissioning again.
Switching the pump off
1. Remove the mains plug from the plug socket.
2. Close all the closing off devices (valves, spray
nozzles, water cock) in the pressure line.
ADVICE
The pump switches off automatically
when the set switch-off pressure is
achieved.
CAUTION!
Danger of injury from hot water
In extended use against the closed pres-
sure side (>10 min.), the water in the
pump can be severely heated up and can
be emitted in an uncontrolled manner!
Isolate the unit from the mains and allow
the pump and water to cool down. Start
the unit again only after all the faults have
been rectified!
The risk of injury from hot water can arise if:
the installation is not correct
the pressure side is closed off
there is a lack of water in the suction line, or if
the pressure switch is defective.
Procedure
1. Isolate the unit from the mains and allow the
pump and water to cool down.
2. Check the unit, the installation and water le-
vel.
3. Start the unit again only after all the faults
have been rectified!
MAINTENANCE AND CARE
Check the air pressure in the storage vessel
CAUTION!
Check the air pressure in the storage
vessel at regular intervals. It must not ex-
ceed 1.5 bar (see Section "Commissio-
ning: Checking the Air Pressure in the
Storage Vessel").
CAUTION!
If the display shows the information
ALARM and REFILL 1.5 BAR, you need
to top up the air in the diaphragm stor-
age vessel. When the correct pressure is
achieved, th display shows ALARM and
AIR PRESSURE OK.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

al-ko-6000-fms-premium

Suche zurücksetzen

  • Mein Alko 6000 FMS premium schaltet sich immer aus. ( der druck fällt ab ) !
    Was kann ich machen ? Eingereicht am 19-3-2020 09:34

    Antworten Frage melden
  • Kann ich bei dem HW ALKO 6000 den Abschaltdruck von 4 atü auf zB.5 atü und den Einschaltdruck von 2 atü auf zB. 3 atü erhöhen Eingereicht am 28-7-2017 16:08

    Antworten Frage melden
  • bei meinem alko 6000 fms premium befindet sich luft im gerät sodass nur wenig bzw unregelmässig druck aufgebaut wird Eingereicht am 19-6-2017 21:48

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Al-ko 6000 FMS premium wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info