541378
11
Zoom out
Zoom in
Vorherige Seite
1/32
Nächste Seite
WZ20S User Guide 11
NO USER SERVICEABLE PARTS INSIDE.
SUPPLY VOLTAGE RANGE:
100 - 240V
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
47-63Hz ~ 30W MAX
WARNING - THIS APPARATUS MUST BE EARTHED.
REFER TO USER GUIDE BEFORE CONNECTING SUPPLY
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
REPLACE FUSE WITH SAME TYPE AND RATING
WARNING: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
100 - 240V~ T500mA 250V 20mm
CAUTION
FUSE
OFF
AC MAINS IN ~
ON
~
Connecting Mains Power
Read the SAFETY INSTRUCTIONS printed at the
front of this User Guide. Check that the correct
mains lead with moulded plug has been supplied
with your console. The power supply
accommodates mains voltages within the range
100-240V without changing any fuses or settings.
It is standard practice to turn connected power
amplifiers down or off before switching the
console on or off. Ensure that the IEC mains plug
is pressed fully into the rear panel socket before
switching on.
Earthing
The connection to earth (ground) in an audio system is important for two reasons:
1. SAFETY - To protect the operator from high voltage shock, and
2. AUDIO PERFORMANCE - To minimise the effect of earth
(ground) loops which result in audible hum and buzz, and to
shield the audio signals from interference.
For safety it is important that all equipment earths are connected to mains earth so that
exposed metal parts are prevented from carrying high voltage which can injure or even kill
the operator. It is recommended that the sound engineer check the continuity of the
safety earth from all points in the system including microphone bodies, guitar strings,
connector cases, equipment panels and so on.
The same earth is also used to shield audio cables from external interference such as the
hum fields associated with power transformers, lighting dimmer buzz, and computer
radiation. Problems arise when the signal sees more than one path to mains earth. An
‘earth loop’ (ground loop) results causing current to flow between the different earth paths.
This condition is usually detected as a mains frequency audible hum or buzz.
To ensure safe and trouble-free operation we recommend the following:
Have your mains system checked by a qualified electrician. If the supply earthing
is solid to start with you are less likely to experience problems.
Do not remove the earth connection from the console mains plug. The console
chassis is connected to mains earth through the power cable to ensure your safety.
Audio 0V is connected to the console chassis internally. If problems are encountered
with earth loops operate the audio ‘ground lift’ switches on connected equipment
accordingly, or disconnect the cable screens at one end, usually at the destination.
Use low impedance sources such as microphones and line level equipment rated at
200 ohms or less to reduce susceptibility to interference. The console outputs are
designed to operate at very low impedance to minimise interference problems.
Use balanced connections where possible as these provide further immunity by
cancelling out interference that may be picked up on long cable runs. To connect an
unbalanced source to a balanced console input, link the cold input (XLR pin 3 or jack
ring) to 0V earth (XLR pin 1 or jack sleeve) at the console. To connect a balanced
console output to an unbalanced destination, link the cold output to 0V earth at the
console.
Use good quality cables and connectors and check for correct wiring and reliable
solder joints. Allow sufficient cable loop to prevent damage through stretching.
If you are not sure ... Contact your service or local Allen & Heath agent for advice.
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Allen-Heath MixWizard Series WZ20S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info