665477
7
Zoom out
Zoom in
Vorherige Seite
1/15
Nächste Seite
EG
I
F
D
E
P
OPERATING INSTRUCTIONS • ISTRUZIONI D’USO
NOTICE D’UTILISATION • BEDIENUNGSANLEITUNG
INSTRUCCIONES DE USO • MANUAL DE INSTRUÇÕES
ΟΔΗΛΙΕΣ XPHΣΕΩΣ
37.4254.075.00 11/2015
Split air conditioner system • Condizionatore d’aria split system
Climatiseurs split • Split-klimagerät
Acondicionador de aire de consola partida sistema split • Aparelho de ar condicionado-Sistema Split
DIAIROUMENES MONADES KLIMASMOU
SDIAS8DC
SDIBS9DC
GR
2
The following symbols used in this manual, alert you
to potentially dangerous conditions to users, service
personnel or the appliance:
This symbol refers to a hazard or unsafe practice which
can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can
result in personal injury or product or property damage.
This air conditioner is equipped with cooling, drying, heating and fan only functions.
Details on these functions are provided below; refer on these descriptions when using the air conditioner.
CONTENTS
NAME OF PARTS AND OPERATION SELECTOR SWITCH 3
INSTALLATION LOCATION 4
ELECTRICAL REQUIREMENTS 4
SAFETY INSTRUCTIONS 4
USING THE REMOTE CONTROL UNIT 4
REMOTE CONTROL UNIT 5
HOW TO SET THE PRESENT TIME 6
COOLING 6
HEATING 6
AUTOMATIC OPERATION 6
DEHUMIDIFYING (DRY) 7
FAN ONLY 7
ADJUSTING THE FAN SPEED 7
NIGHT MODE/ENERGY SAVING 7
HIGH POWER MODE 7
SETTING THE TIMER 8
SETTING THE 1 HOUR TIMER 8
SETTING THE HOLIDAY TIMER 8
OPERATION WITHOUT THE REMOTE CONTROL UNIT 9
CARE AND CLEANING 9
TIPS FOR ENERGY SAVING 10
TROUBLESHOOTING 10
EXPLANATION AND USE OF THE REMOTE CONTROL UNIT’S MICROSWITCHES
14
NOTE
PRODUCT INFORMATION
If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate on the bottom
of the cabinet.
Model No.
Serial No.
Date of purchase
Dealer’s address
Phone number
ALERT SYMBOLS
EG
WARNING
CAUTION
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
– Low voltage no. 2006/95/EC (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010
+ A15:2011).
Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) +
A1(2009) + A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer’s
installation and/or operating instructions.
3
1. Remote control unit.
2. Remote control sensor: Detects the room temperature
around the remote control unit, the air conditioner is
controlled accordingly.
3. Air outlet: Conditioned air is blown out of the air
conditioner through the air outlet.
4.
Air intake: Air from the room is drawn into this section
and passes through air filter which removes dust.
5. Remote control receiver: This section picks up infrared
signals from the remote control unit (Transmitter).
6. Operation selector (without remote control): Push
the button to walk through the operation modes (OFF,
COOL and HEAT)
7. OPERATION lamp: This lamp lights up during
operation.
It blinks once to announce that the remote control
signal has been received and stored.
8. STANDBY lamp: This lamp lights up when the air
conditioner is connected to the power and ready to
receive the remote control command.
9. TIMER lamp: This lamp lights up when the system is
being controlled by the timer.
10. Air filter.
The OFF position does not disconnect the power. Use
the main power switch to turn off power completely.
WARNING
EG
NAME OF PARTS AND OPERATION SELECTOR SWITCH
5
6
7
8
9
4
3
10
2
1
NOTA
When the unit receives a signal from the remote
controller, all the three lamps (OPERATION, TIMER
and STANDBY) light up for a moment to indicate the
correct signal reception.
OFF LAMPS FUNTION
It is possible to set the air conditioner in order to let the
OPERATION, TIMER and STANDBY lamps always OFF,
even during operation.
Be sure that the remote controller is ON (using the ON/
OFF button) and that the symbol on the display of
remote controller is OFF, then Press contemporary the
IFEEL and FAN buttons on the remote control unit for more
then 5 seconds.
Repeat the same procedure to set again the normal
operation conditions.
If the air conditioner is powered, but the lamps are off, try
to activate them using this procedure.
In case of troubleshooting the air conditioner diagnostic
system activates the lamps accordingly, even if they are
set to OFF. See paragraph TROUBLESHOOTING for
further details.
The blinking of TIMER and STANDBY lamps and
OPERATION lamp ON, indicates that:
1. Indoor unit has not been addressed.
2. Heating mode has been selected, when the system
was in cooling mode, or vice versa.
Select the correct mode, compatible with the
system.
SEE AUTO-DIAGNOSIS TABLE
MULTI SPLIT SYSTEM
only
4
EG
SAFETY INSTRUCTIONS
l
Read this booklet carefully before using this air
conditioner. If you still have any difficulties or
problems, consult your dealer for help.
l
This air conditioner is designed to give you
comfortable room conditions. Use this only for its
intended purpose as described in this Instruction
Manual.
l
Never use or store gasoline or other flammable vapor or
liquid near the air conditioner. It is very dangerous.
l
Never install electrical equipment, which is not
protected with IPX1 protection (protection against
vertical water drop), under the unit.
l
The manufacturer assumes no responsabilities if the
safety regulations or local codes are not observed.
l
Never use the power main switch to start or stop the
air conditioner: always use the ON/OFF button on the
remote control unit or the selector switch on the unit.
l
Do not let children play with the air conditioner.
l
Do not cool the room too much if babies or invalids
are present.
l
This air conditioner is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the air conditioner
by a person responsible for their safety.
WARNING
CAUTION
INSTALLATION LOCATION
l
We recommend this air conditioner to be installed
properly by qualified installation technicians in
accordance with the installation instructions
provided with the unit.
l
Do not install this air conditioner where there are
fumes or flammable gases, or in an extremely humid
space such as a green house.
l
Do not install the air conditioner where excessively
high heat-generating objects are placed.
l
Do not install the air conditioner where the
atmosphere is extremely damp or humid (e.g.
greenhouse or laundry) it could be wetted by drops
of water (i.e. in laundries).
l
To protect the air conditioner from heavy corrosion,
avoid installing the outdoor unit where salty sea
water can splash directly onto it or in sulphurous
air near a spa.
WARNING
ELETRICAL REQUIREMENTS
l
Before installation, check that the voltage of the electric
supply in your home or office is the same as the voltage
shown on the nameplate.
l
All wiring must conform to the local electrical codes.
Consult your dealer or a qualified electrician for details.
l
Each unit must be properly grounded with a ground (or
earth) wire or through the supply wiring.
l
Wiring must be done by a qualified electrician.
HOW TO INSTALL BATTERIES
l Remove trhe lid in the rear part of the remote control
unit and check the settings of the four microswitches
as shown below:
TEMPERATURE SENSOR SELECTOR
l
Under normal conditions the room temperature is
detected and checked by the temperature sensor placed
in the remote controller (I FEEL icon displayed ).This
function is designed to provide a comfortable room
temperature by transmitting the temperature control
command from the location next to you. When using this
function, the remote, control should always be pointed
at the air conditioner, therefore it should be placed in
a position in which it is visible by the indoor unit (for
example, do not put it in a drawer).
l
It is possible to disable the remote controller room
sensor pressing the I FEEL button. In this case the I
FEEL icon on the remote controller display lights off and
only the sensor placed in the air conditioner becomes
active.
USING THE REMOTE CONTROL UNIT
l
Insert two AAA alkaline batteries of 1,5 V-DC making
sure that point in the direction marked in the battery
compartment.The displayed time flashes.
Press the SEL TYPE button.
Remote controller is now ready for operation.
l
The batteries last average more than six months,
anyway it depends on how much you use the remote
control unit.
Remove the batteries if you do not use the remote
control unit for more than one month.
Replace the batteries when the remote control unit
lamp fails to light, or when the air conditioner does not
receive the remote control unit signals.
l
The batteries of the remote control contain polluted
substances. Exhausted batteries must be disposed
according to the laws in force.
OPERATION WITH THE REMOTE CONTROL UNIT
When using the remote control unit, always point the unit
transmitter head directly at the air conditioner receiver.
HOW TO TURN ON THE AIR CONDITIONER
Press the ON/OFF button to turn the air conditioner on.
The operation lamp will light up, indicating the unit is in
operation.
The remote control unit transmits signals to the
indoor unit each time you press a key and at any
temperature change detected by the IFEEL sensor. In
case of troubles (low batteries, remote control placed
in a position not visible by the indoor unit,...) room
temperature control is automatically switched to the
sensor of the indoor unit. In this case, the temperature
around the remote control unit may differ from the
temperature detected in the air conditioner position.
NOTE
SWITCHES
NOTE
IF YOU INSTALL MORE THAN ONE INDOOR
UNIT IN THE SAME ROOM:
It is possible to utilise only one remote control for all
the units.
On the contrary, if you want to address each remote
control to its unit, follow the procedure”Remote control
unit/indoor unit address” (see Installation Instructions).
PLEASE, SEE THE END
OF THIS MANUAL FOR
DETAILS
5
EG
REMOTE CONTROL UNIT
DISPLAY
Information is displayed when the remote controller is switched
on. If switched off, only the operating mode, the room temperature
and the clock are shown
Operation mode
Fan speed
High speed
Automatic
Medium speed
Low speed
Displayed when
transmitting data
Set point
temperature
I FEEL mode is active
(remote controller
sensor active)
Timer modes
Automatic
Cooling
Heating
Dehumidification
Fan
C
Clock
Room
temperature
Night
mode
Oscillation
Flap
Filter Ti0
2
is ON
HIGH POWER
mode
TRANSMITTER
When you press
the buttons of the
remote control unit,
the mark
appears on the
display to transmit
the setting changes
to the receiver in the
air conditioner.
HOURS AND MINUTES SETTING
BUTTONS
With these buttons is possible to set the
clock and the timer. For details refer to
paragraphs “ SETTING THE HOUR” and
“SETTING THE TIMER”.
TIMER SELECTION BUTTON
Press this button to select the type of
timer to activate. For details refer to
paragraph “SETTING THE TIMER”.
C
TEMPERATURE SETTING BUTTONS
- (cooler)
Press this button to decrease the set
temperature.
+ (warmer)
Press this button to increase the set
temperature.
SENSOR
A temperature
sensor inside the
remote control unit
detects the room
temperature.
CLOK AND TIMER SETTING BUTTON
Press this button in order to:
• set the clock
• set the ON/OFF timer
For details refer to paragraphs “SETTING
THE HOUR” and “SETTING THE TIMER”.
IFEEL/IFEEL C SENSOR SELECTOR
Press this button to modify the active
setting for room temperature detection
(from remote controller to air conditioner
and viceversa).
“FAN “ BUTTON (fan speed)
Fan speed is automatically
selected by the
microcomputer.
High speed.
Medium speed.
Low speed.
ON/OFF BUTTON
This button turns the air conditioner ON
and OFF.
FLAP BUTTON
NOT AVAILABLE
NIGHT/ECO BUTTON
Press this button in order to select the
NIGHT/ECO mode.
“HIGH POWER” BUTTON
Press this button in order to select the
HIGH POWER mode.
MODE SELECTOR BUTTON
Press this button to modify the air
conditioner mode.
(cooling)
The air conditioner makes the room
cooler.
(dry)
The air conditioner reduces the humidity
in the room.
(automatic)
When this setting is selected (+ IFEEL
ON), the unit calculates the difference
between the thermostat setting and
the perceived room temperature and
automatically switches to the “cool” or
“heat” mode.
(fan)
The air conditioner works only as a
circulation fan.
Inverter model
MENU BUTTON
Use this button in order to enter the
functions menu.
MODE SELECTOR BUTTON
Press this button to modify the air
conditioner mode.
(heating)
The air conditioner makes the room
warmer.
Fixed symbol: the fan stops when the set
temperature is exceeded.
Blinking symbol (HEATING
RECIRCULATION FUNCTION): the
fan keeps running even after the set
temperature is exceeded.
(automatic)
When this setting is selected (+ IFEEL ON),
the unit calculates the difference between
the thermostat setting and the perceived
room temperature and automatically
switches to the “cool” or “heat” mode.
6
EG
AUTOMATIC OPERATION
DEFROSTING OF OUTDOOR UNIT HEAT
EXCHANGER
When the outdoor temperature is low, frost or ice may
appear on the heat exchanger coil, reducing the heating
performance. When this happens, a protection function
for the heat exchanger defrosting is activated. During this
function operation, the fan of the indoor unit stops. Heating
operation restarts after several minutes. (This interval
will vary slightly depending on the room and outdoor
temperature).
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat
from outside air. The heating efficiency will fall off when
the outdoor temperature is very low. If enough heat is not
obtained with this air conditioner, use another heating
appliance in conjunction with it.
Example of operation diagram in the (Auto) mode
with the set room temperature at 23°C.
NOTE
The air conditioner changes the operation mode (from cool
to heat or vice versa, if one of the following conditions
occurs:
- ZONE A: changes if the difference between the room
temperature and the temperature set on the remote
control unit is at least 3°C..
- ZONE B: changes if the difference between the room
temperature and the temperature set on the remote
control unit is at least 1°C, one hour after the compressor
stop.
- ZONE C: never changes if the difference between the
room temperature and the temperature set on the remote
control unit is no more than 1°C.
1. Set the or selector to AUTO (symbol on the
display; also the symbol or remains displayed).
2. Press the
+/- buttons (temperature selection)
to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
When this setting is selected, the air conditioner will operate
automatically switching to the COOL or HEAT mode as
appropriate (regardless of the symbol displayed).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
3. Press the FAN selector button to the setting you want.
During Automatic Operation (+ IFEEL ON) the set
temperature is understood as perceived one, then the
system is automatically adjusted not only according to the
air temperature, but also based on the relative humidity,
according to the “humidex” index.
Verify that the unit is connected to the
main power and the STANDBY lamp is
light up.
1. Set the selector to COOL (symbol
on the display).
2. Press the +/- buttons (temperature
selection) to set the desired temperature
(the temperature range is between 32 °C
max. and 10 °C min.).
HOW TO SET THE PRESENT TIME
HEATING
1. Press the button ST three times.
The time indication alone flashes.
2. Press the H button until the present time hour is
displayed. Press the M button until the present time
minutes are displayed. The display will automatically
stop flashing.
1. Set the selector to HEAT (fixed or blinking symbol
on the display.
2. Press the +/- buttons (temperature selection) to set
the desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
3. Press the FAN button to select the fan speed.
For several minutes after the start of heating operation, the
indoor fan will stop until the indoor heat exchanger coil has
warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period,
the STANDBY lamp remains lit.
NOTES
COOLING
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
3. Press the FAN button to select the fan speed.
NOTE
C
1
3
2
2
1
Generally the fan stops when the set temperature is
exceeded (when you have selected the fixed HEATING
symbol ).
HEATING RECIRCULATION FUNCTION
If you want to let the fan run even after the set temperature is
exceeded, for example, in order to make the heating, coming
from a nearby source, circulate (eg. fireplace installed under
the air conditioner), press the selector until the blinking
HEATING symbol is displayed.
ONON ON
1 H 1 H
MIN.MAX.
A
B
C
C
B
A
27
26
25
24
23
22
21
20
19
7
EG
1. Set the button to DRY. The icon is displayed.
2. Press the
+/- buttons (temperature selection)
to set the
desired temperature (the temperature range is between
32 °C max. and 10 °C min.).
DEHUMIDIFYING (DRY)
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
AFTER 5 SECONDS FROM THE
REQUIRED TEMPERATURE SETTING
THE DISPLAY WILL SHOW THE ROOM
TEMPERATURE AGAIN.
l
Use DRY operation when you want to reduce the humidity
in the room.
l
Dehumidifying operation is adjusted both by the difference
between set temperature and air temperature, and by the
value of relative humidity, detected by the sensor.
l
During DRY operation, the fan speed is automatically
set (Remote control lamp is ON) to prevent
overcooling.
l
Dry operation is not possible if the indoor temperature is
10 °C or less.
l
When room temperature is above set value, the unit
operates to dehumidificate so efficient as possible.
l
When room temperature is below set value, the unit will
not stop, it will proceed operating with low power to
dehumificate and, in small spaces, temperature could
drop below the set temperature.
NOTE
FAN ONLY
If you want to make air circulate without any temperature
control, press button until only the fan symbol
appears on the display.
ADJUSTING THE FAN SPEED
AUTOMATIC
Simply set the FAN selector to the position.The unit
automatically controls the fan speed when the AUTO mode
is selected. When the air conditioner starts operating, in
heating or cooling, the fan speed varies according to the
thermal load of the room.
MANUAL
If you want to manually adjust speed just set the FAN
selector as desired.
High speed Med. speed Low speed
AUTOMATIC OPERATION IN MULTISPLIT
CONFIGURATION
When the air conditioning system configuration is multisplit
and there is more than one indoor unit connected, the
automatic mode operates as follows:
- the first unit that switches on the system also decides the
operation mode (cooling or heating) for all the other units
that will be switched on after the first one;
- when the system has been switched on in cooling mode
and one unit is activated in heating mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in “automatic” mode and the
desired temperature is lower than the detected ambient
temperature, the unit will operate in cooling mode, like the
other units of the system; on the contrary, if the desired
temperature is higher than the detected one, the unit will
operate in fan mode;
- when the system has been switched on in heating mode
and one unit is activated in cooling mode, an error will
be signaled for this unit (wrong operating mode). If the
same unit is switched on in “automatic” mode and the
desired temperature is higher than the detected ambient
temperature, the unit will operate in heating mode, like the
other units of the system; on the contrary, if the desired
temperature is lower than the detected one, the unit will
operate in fan mode.
NIGHT MODE / ENERGY SAVING
l
This mode enables you to save energy.
1. Set the or selector to cool, dry or heat.
2. Press the button.
3.
The mark appears on the display. Press the
button again to release the function.
What does the NIGHT mode mean?
When you select the NIGHT mode, the air conditioner will
modify automatically the set temperature after 60 minutes.
This enables you to save energy without sacrificing your
comfort.
OPERATING MODE SET TEMPERATURE CHANGE
Heating Lowered by 2 °C
Cooling and Dry Raised by 1 °C
During the NIGHT mode the internal fan speed is
automatically lowered and reduces the noise.
NOTA
NOTE
During the high power operation the room temperature
could not correspond to the set temperature.
HIGH POWER MODE
When this mode is active the internal fan speed is set
automatically and the air conditioner operates at the
maximum power in the selected operating mode (cooling
or heating).
1. Press the HIGH POWER button.
3. The mark appears on the display.
Press the button
again to release the function.
.
9
EG
FILTER CLEANING
Use a vacuum cleaner to remove light dust. If there is
sticky dust on the filter, wash the filter in lukewarm,
soapy water, rinse it in clean water, and dry it.
AIR FILTER
l Never use solvents, or harsh chemicals when cleaning
the indoor unit. Do not wipe the plastic casing using very
hot water.
l Some metal edges and the vanes are sharp and may
cause injury if handled improperly; be especially careful
when you clean these parts.
l The internal coil and other components of the outdoor
unit must be cleaned every year. Consult your dealer or
service centre.
CAUTION
2. WHEN THE AIR CONDITIONER IS RUNNING
If you want to turn off the air conditioner push the
OPERATION selector with a pen until the OPERATION
lamp is turned off.
Power failure during operation.
In the event of power failure, the unit will stop. When the
power is resumed, the unit will restart automatically after
3 minutes.
NOTE
If you have lost the remote control unit or it has troubles,
follow the steps below.
1. WHEN THE AIR CONDITIONER IS STOPPED
If you want to turn on the air conditioner push the
OPERATION selector with a pen to select the desired
mode (COOL or HEAT).
OPERATION WITHOUT THE REMOTE
CONTROL UNIT
The air conditioner will start in HIGH fan speed.
The temperature setting is 25°C for cooling mode and
21°C for heating mode.
NOTE
CARE AND CLEANING
l
Maintenance operations must be carried out by specially
trained personnel.
l
For safety, be sure to turn the air conditioner off and also
to disconnect the power before cleaning.
l
Do not pour water on the indoor unit to clean it. This will
damage the internal components and cause an electric
shock hazard.
WARNING
CASING AND GRILLE (INDOOR UNIT)
Clean the casing and grille of the indoor unit with a vacuum
cleaner brush, or wipe them with a clean, soft cloth.
If these parts are stained, use a clean cloth moistened with
a mild liquid detergent.
When cleaning the grille, be careful not to force the vanes
out of place.
OPERATION
selector
The air filter should be cleaned at least once every
six months or more frequently; it depends on the real
operation conditions.
1. Remove the screw.
2. Remove the filter and clean it.
3. Insert the filter again and fix the screw.
10
EG
TIPS FOR ENERGY SAVING
DO NOT:
l
Block the air intake and outlet of the unit.
If they are obstructed, the unit will not work well, and
may be damaged.
l
Let direct sunlight into the room. Use sunshades,
blind or curtain.
DO:
l
Always try to keep the air filter clean. A clogged filter
will impair the performance of the unit.
l
To prevent conditioned air from escaping, keep
windows, doors and any other openings closed.
TROUBLESHOOTING
WARNING
l
The use of portable telephones near the air conditioner
may cause disturbance to its normal operation and must
be avoided. In case abnormal operation is noticed,
(OPERATION lamp lights, but the air conditioner will not
run) to restore normal operation turn-off electric supply
for about 3 minutes, by disconnecting the main switch
or the wall plug, then start again the air conditioner.
If your air conditioner does not work properly, first check
the following points before requesting service.
If it still does not work properly, contact your dealer or
service centre.
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Operation button is OFF.
4. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service centre.
3. Press the button again.
4. Replace batteries.
Trouble: Poor cooling or heating performance.
Possible cause:
1. Dirty or clogged air filters.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. The set temperature on the remote control unit is too
high.
6. Outdoor temperature is too low (heat pump version).
7. Defrosting system does not work (heat pump version).
Remedy:
1. Clean air filters to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the right temperature on the remote control unit.
6. Try to use a back-up heater.
7. Consult your dealer.
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. During operation, any plastic parts may expand or
shrink due to a sudden temperature change. In this
event, a clicking sound may occur.
Remedy:
1. This is normal, and the sound will disappear when an
even temperature is settled.
11
EG
ERROR
LEDS
OPERATION TIMER STANDBY
POSSIBLE CAUSE SYSTEM BEHAVIOUR SOLUTION
E0
l
F F
Unit has not been addressed correctly.
Operating mode selected is not
compatible with the system (ex. heating
mode has been selected, when the
system was in cooling mode, or vice
versa).
Fan is stopped and flap is closed.
The system restarts automatically
as soon as the unit is addressed
correctly.
Fan is stopped and flap is closed.
The system restarts automatically
as soon as a correct operating
mode is selected.
Set the outdoor/indoor unit refrigerant
circuit address (see Installation
Instructions)
Select an available or compatible
mode with the other units of the
system.
E1
O O F
Error on the outdoor unit. Fan is stopped and flap is closed.
The system restarts automatically
as soon as the problem on the
outdoor unit is solved.
Check the error code using the
appropriate LEDs on the PCB of the
outdoor unit.
Follow the indications of the diagnosis
for the outdoor unit.
AUTO-DIAGNOSIS TABLE
O = LED OFF
l
= LED ON F = Flashing LED
12
EG
ERROR
LEDS
OPERATION TIMER STANDBY
POSSIBLE CAUSE SYSTEM BEHAVIOUR SOLUTION
E3
F F F
Communication error between the
outdoor unit and the indoor unit
Fan is stopped and flap is closed
after 30 seconds of missing
communication.
The system restarts automatically
as soon as the communication is
recovered.
Check that connections between C1
and C2 on outdoor and indoor terminal
block are correct (C1 terminals
connected together, C2 terminals
connected together).
Check that a shielded communication
cable has been used.
Check that the dip-switch SW2 for
communication address setting is in
the correct position.
Check that all earth cables are
properly connected to every terminal.
Check that the shield of the
communication cable is properly
connected to every terminal.
Check the communication fuse on
outdoor and indoor unit.
Check that the outdoor unit has power
supply and that it is working.
Check that all PCBs are powered on.
Be sure that power supply has not
been connected to the communication
terminals.
Check that there are no burnt signs
on the PCBs, in particular close to
communication cables.
Check that the fan motor is not
damaged and it doesn’t create short
circuit on the indoor PCB.
O = LED OFF
l
= LED ON F = Flashing LED
13
EG
ERROR
LEDS
OPERATION TIMER STANDBY
POSSIBLE CAUSE SYSTEM BEHAVIOUR SOLUTION
E4
F F O
Defective or not connected indoor coil
temperature sensor.
Fan is stopped and flap is closed.
The system restarts automatically
as soon as the sensor is repaired.
Check that the sensor is properly
connected to the PCB as shown in
the electrical wiring diagram.
Check that the sensor is not damaged
and, if necessary, replace it.
E5
F O F
Defective or not connected room air
temperature/humidity sensor.
Fan is stopped and flap is closed.
The system restarts automatically
as soon as the sensor is repaired.
Check that the sensor is properly
connected to the PCB as shown in
the electrical wiring diagram.
Check that the sensor is not damaged
and, if necessary, replace it.
E6
O F F
Fan motor error. Fan is stopped and flap is closed.
The system restarts automatically
after some seconds.
Check that the fan motor is properly
connected to the PCB as shown in the
electrical wiring diagram.
Check that the fan motor is not locked.
Check that the fan motor is not
damaged and, if necessary, replace it.
E8
O F O
Combination between outdoor unit and
indoor units is not correct.
Fan is stopped and flap is closed.
Check that you have selected, during
the installation of the system, a proper
combination between outdoor unit
and indoor units.
Check that none of the indoor units
of the system has a communication
error. If present, first solve this error.
NOTE: If the trouble is not solved with the above actions, contact your service centre.
O = LED OFF
l
= LED ON F = Flashing LED
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN
DIRECTIVE 2012/19/EU
At the end of its working life this equipment must not be disposed of as an household waste.
It must be taken to special local community waste collection centres or to a dealer providing this service.
Disposing of an electrical and electronic equipment separately avoids possible negative effects on the environment
and human health deriving from an inappropriate disposal and enables its components to be recovered and recycled
to obtain significant savings in energy and resources.
In order to underline the duty to dispose of this equipment separately, the product is marked with a crossed-out dustbin.
INFORMATION FOR CORRECT DISPOSAL OF THE BATTERY IN ACCORDANCE WITH THE EUROPEAN
DIRECTIVE 2006/66/EC
Please replace battery when its electricity charge is used up: please do not eliminate this battery together with normal
household waste. It must be taken to special local community waste collection centres or to a dealer providing this
service. Disposing of a battery separately avoids possible negative effects on the environment and human health
deriving from an inappropriate disposal and enables its components to be recovered and recycled to obtain significant
savings in energy and resources. In order to underline the duty to dispose of this equipment separately, the battery
is marked with a crossed-out dustbin.
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with a global warming potential (GWP) of
2087.50. Do not release R410A into the atmosphere.
EXPLANATION AND USE OF THE REMOTE CONTROL UNIT’S MICROSWITCHES
Switch 1 and 2: These switches are used to match the remote control with the
specific internal units.
Switch 3 and 4: these switches have been provided for future use; they have no
function today. Keep them in OFF position.
Switch 5 and 6: these switches set the remote control in WIRELESS or WIRED
mode. Default position is ON (WIRELESS mode). For WIRED control, remove the
batteries and set in OFF position.
HOW TO REMOVE BATTERIES
l Remove the lid.
l Press the battery toward the negative end
and lift it out by its positive end (as shown
in the figure).
l Remove the other battery in the same way.
14
EG
Via Varese, 90 - 21013 Gallarate - Va - Italy
Tel. +39 0331 755111 - Fax +39 0331 776240
www.argoclima.com
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Argo SDIAS8DC wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Argo SDIAS8DC

Argo SDIAS8DC Installationsanweisung - Deutsch - 76 seiten

Argo SDIAS8DC Bedienungsanleitung - Deutsch - 15 seiten

Argo SDIAS8DC Installationsanweisung - Englisch, Französisch - 76 seiten

Argo SDIAS8DC Bedienungsanleitung - Französisch - 15 seiten

Argo SDIAS8DC Installationsanweisung - Italienisch, Portugiesisch, Spanisch - 76 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info