702278
6
Zoom out
Zoom in
Vorherige Seite
1/36
Nächste Seite
Closing ATS1234 Wireless DGP housing
1. Replace the plastic cover. Make sure the cover tamper
switch extension spring is in place on the tamper switch.
2. Mount sensors and 868 MHz FM repeater (a repeater can be
added later if sensor performance or signal strength is
found to be inadequate).
Powering up the ATS1234 Wireless DGP
Before powering up the panel and receiver module:
1. Verify that all wiring at the panel and ATS1234 wireless
receiver is correct.
2. Connect the panel backup battery and AC power.
Verify that the RF/Power LED is on. For troubleshooting refer to the
chapter Testing and Installation Troubleshooting.
Output numbering
The output numbering of a Wireless DGP is in line with all DGPs
(please refer to Table 1), but the Wireless DGP has no physical
outputs or output expansion available. However, any available
output can be programmed in the range of 1 – 255 via key fob
programming in menu 6.
Remember that in standard DGP mode the first relay of each
DGP (relay 17 for DGP 1) can be used to mask supervision on
sensors by using time zones to energise/de-energise the virtual
relay (see Menu option 11 – Supervision Options).
Table 1. Output numbering.
Control panel 1 - 16 DGP 8 129 - 144
DGP 1 17 - 32 DGP 9 145 - 160
DGP 2 33 - 48 DGP 10 161 - 176
DGP 3 49 - 64 DGP 11 177 - 192
DGP 4 65 - 80 DGP 12 193 - 208
DGP 5 81 - 96 DGP 13 209 - 224
DGP 6 97 - 112 DGP 14 225 - 240
DGP 7 113 - 128 DGP 15 241 - 255
Zone numbering
The Wireless DGP zone database can be set up as either a 16-zone
or 32-zone database. This means you can add up to 16 or up to 32
wireless devices to the DGP. If the DGP 1 is been programmed with
32 zones, then the next 16 zones (33-48) normally belonging to DGP
2 will now belong to DGP 1 and the RAS display would show 17-48
(for more details, refer to Table 2 and Menu 14, DGP settings).
Table 2. Zone numbering.
Control panel 1 - 16 DGP 8 129 - 144
DGP 1 17 - 32 DGP 9 145 - 160
DGP 2 33 - 48 DGP 10 161 - 176
DGP 3 49 - 64 DGP 11 177 - 192
DGP 4 65 - 80 DGP 12 193 - 208
DGP 5 81 - 96 DGP 13 209 - 224
DGP 6 97 - 112 DGP 14 225 - 240
DGP 7 113 - 128 DGP 15 241 - 256
Introduction to the programming (see fig.r)
Each sensor must be programmed into the Wireless DGP database
via an ATS control panel RAS keypad. In this procedure it is
assumed that:
Sensor / key fob documentation is available or known.
The DIP switch address for the Wireless DGP is set correctly.
The DGPs database size has been correctly selected. The
factory default sets the DGP to 16 detectors.
If planned to have 32 detectors on the DGP, you first need to
change the option in menu 6 from 16 to 32 before learning any
sensor!
Sensors are physically installed or mounted.
The repeater has been installed and programmed if
required.
The specific details per sensor need to be reviewed in the related
component sheet. In general, you need to know that the sensor can
be learned into the system by creating a tamper on the detectors
and door window sensors and for key fobs that you need to press
the matching two buttons at the same time during the auto learning
when in the proper menu (see further on for details).
Programming (see fig.r)
Selecting the Remote Wireless DGP Menu (Panel menu)
The ATS1234 provides a menu through which a number of options
can be set. This menu is an internal DGP menu (see the menu tree
on figure
r). In addition the status of the ATS1234 itself or inputs
can be viewed.
To enter the programming menu for the ATS1234:
1. Enter menu 28 of the Control Panel installer menu.
2. Press 1 [ENTER] followed by the DGP address selected and
[ENTER] to enter the DGP menu. The display now shows
"ATS1234" followed by the version number.
3. Press [ENTER] to proceed to the menu or press the menu
number followed by [ENTER] to go to a menu item directly.
Programming a sensor with single zone
The menu has a generic approach for future sensors. At the
moment 868 FM does not have devices with more than one
zone, please select 1!
Zone numbering and sensors
The input numbers used are related to the address selected (see
Zone numbering on page 6).
To view the status, enter the first input to view. The selected input
status is shown. Press [*MENU] to view the previous or [ENTER] to
view the next input.
How to configure a wireless sensor and program a zone
Enter the Installer Menu 19
1. MENU Key, Installer PIN, ENTER
2. 19 ENTER
3. * (Advanced Installer Menu)
Enter the Remote Device Menu
4. 28 ENTER
Select the Wireless DGP and its Menu
5. 1 ENTER (1-DGP, 2-RAS)
6. 1 ENTER (DGP No)
7. 15 ENTER (Set Factory Defaults if not empty!)
8. * (Confirm)
9. 2 ENTER
10. 17 ENTER
11. 1 ENTER (always 1 zone)
12. Press Program Switch (tamper the sensor)
13. Keypad will beep 2 times to confirm that the zone has
learned properly
14. If ready press 0 ENTER to leave the zone programming
menu
15. 0 ENTER (exit the DGP menu)
16. 0 ENTER (exit menu 28)
Enter the Installer Menu 19 again
17. ENTER (Simple Menu)
18. 1 ENTER (Zone database)
6
6

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aritech ATS1234 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info