12 ATS7100/7110 Installation and Troubleshooting Guide
Net 064 INFO 033 022
cr=0010 RELEASE COM
Usr 064 RR 034
Figure 5. ISDN D-channel trace of a call from the
ATS7100 to a Central Station
ISDN D-channel X25 monitoring (ATS7110
mode)
The ATS7110 will also display the X25 traffic on the D-
channel, together with the normal ISDN messages. This
is a powerful tool that can be used for troubleshooting.
Typically the first establishment of a connection will look
as follows:
--> 48244
Usr 002 SABME
Net 002 UA
Net 002 INFO 000 000
LCN 0 RESTART REQ Cause 07 Diag 00
Usr 002 RR 001
Usr 002 INFO 000 001
LCN 0 RESTART REQ Cause 00 Diag 00
Usr 002 INFO 001 001
LCN 1 CALL REQ
Net 002 RR 001
Net 002 RR 002
Net 002 INFO 001 002
LCN 1 CALL ACCEPT
Usr 002 RR 002
! Connected
Usr 002 INFO 002 002
LCN 1 DATA
Net 002 RR 003
Net 002 INFO 002 003
LCN 1 RESET REQ Cause 80 Diag 00
Usr 002 RR 003
Usr 002 INFO 003 003
LCN 1 RESET CONF
Usr 002 INFO 004 003
LCN 1 DATA
Net 002 RR 004
Net 002 RR 005
Net 002 INFO 003 005
LCN 1 RESET REQ Cause 80 Diag 01
Usr 002 RR 004
Usr 002 INFO 005 004
LCN 1 RESET CONF
Usr 002 INFO 006 004
LCN 1 DATA
Net 002 RR 006
Net 002 RR 007
Net 002 INFO 004 007
LCN 1 RESET REQ Cause 80 Diag 02
Usr 002 RR 005
Usr 002 INFO 007 005
LCN 1 RESET CONF
Usr 002 INFO 008 005
LCN 1 DATA
Net 002 RR 008
Net 002 RR 009
Net 002 INFO 005 009
LCN 1 RR
Usr 002 RR 006
! TX Response (OK)
Usr 002 INFO 009 006
LCN 1 DATA
Net 002 RR 010
Net 002 INFO 006 010
LCN 1 RR
Usr 002 RR 007
! TX Response (OK)
Usr 002 INFO 010 007
LCN 1 DATA
Net 002 RR 011
Net 002 INFO 007 011
LCN 1 RR
Usr 002 RR 008
! TX Response (OK)
Usr 002 INFO 011 008
LCN 1 DATA
Net 002 RR 012
Net 002 INFO 008 012
LCN 1 RR
Usr 002 RR 009
! TX Response (OK)
Usr 002 RR 009
Net 002 RR 012
The following messages can be displayed by the dialler:
Message Description
! Connected
The dialler is connected to the Central Station
! Connect Failed
The dialler could not establish a connecting to the Central Station.
Please check the phone number. See also the next tables for more
detailed information.
! Disconnected
The dialler is disconnected from the Central Station
! TX Response (OK)
The message was transmitted successfully to the Central Station
Calls may fail for several reasons. These are described below.
When the message SABME is shown for 4 times on the S0 Monitor, followed by the message !Connect Failed, this may
be caused by:
S0 Monitor shows Possible reasons Solution
No ISDN line connected to the dialler Connect ISDN line
Incorrect TEI value programmed Check menu 19.9.11 X25
TEI Value
Usr 002 SABME
Usr 002 SABME
Usr 002 SABME
Usr 002 SABME
! Connect Failed
No X25 (Digi Access Alarm service in the
Netherlands) is present on the ISDN line
Contact Central Station or
PTT
When the X25/Digi Access Alarm (Netherlands) service is present on the ISDN line, but a connection can not be
established, the dialler will display Cause and Diagnostic values to indicate the reason for the problem.
Cause Diag Reason Solution
80 00 No problem. The scrambling algorithm is
synchronizing and resends the message.
-
80 01 No problem. The scrambling algorithm is -
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Aritech ATS7100 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info