COMPRESSOR
COMPRESSORCOMPRESSOR
COMPRESSOR
Compressor oil must be checked in those unit models provided with an oil viewer.
Verify that the compressor refrigerates adequately with the circulating gas (verify the
refrigerant charge).
Verify that the power consumption has not increased.
Verify that the compressor discharge pressure is not too high and that the intake pressure is not
too low.
Verify that the compressor fasteners are not deteriorated.
Verify that no frost develops on the compressor.
CONDENSER
CONDENSERCONDENSER
CONDENSER
Install chemical feeders “downstream” from the heat pump, as far away and at a lower height.
The feeder should never be installed near the intake of the purification pump as this will
damage the condenser.
NEVER introduce concentrated chemical products in the pool skimmers as this will damage the
Titanium condenser.
In climates where temperatures occasionally fall below freezing, circulate the water using the
purification pump to maintain the water temperature above freezing (32º F).
In the case these temperatures are persistent or habitual, the heating and purification system
should be completely drained. The condenser has a lateral plug the purge the system.
FAN
FANFAN
FAN
Verify the flows of the fan each year.
Clean the louvers of the fan as well as the protection grill regularly.
ELECTRICAL PANEL
ELECTRICAL PANELELECTRICAL PANEL
ELECTRICAL PANEL
Verify all electrical connections.
Verify that there is no over-heating of the electrical terminals.
Verify that the protection systems operate correctly.
Verify that the regulator operates correctly and verify the temperature with a mercury
thermometer (calibration probe).
9.
9. 9.
9. REFRIGERANT CHARGE
REFRIGERANT CHARGEREFRIGERANT CHARGE
REFRIGERANT CHARGE
For the procedures described below, we recommend you contact a professional specialised in
heating and air conditioning units.
DRAINING THE COOLING CIRCUIT
DRAINING THE COOLING CIRCUITDRAINING THE COOLING CIRCUIT
DRAINING THE COOLING CIRCUIT
It is imperative to drain the cooling circuit before charging the refrigerant.
First draining procedure:
Connect the gauge tubes to the intake pressure lines of the circuit (low pressure) and to
the return pressure lines (high pressure).
Connect the main line of the gauge to the vacuum pump.
Open all the valves, including the solenoid and the regulating valves.
Open the valves of the gauge (LO = low pressure valve / HI = high pressure valve).
Activate the vacuum pump and wait until the circuit is completely drained.
Close all valves or stopcocks and disconnect the vacuum pump.
REFRIGERANT GAS CHARGE
REFRIGERANT GAS CHARGEREFRIGERANT GAS CHARGE
REFRIGERANT GAS CHARGE
The equipment uses R-407C class refrigerant.
This is the reason why the gas taken from the refrigerant bottle must be introduced in the low-
pressure circuit by means of a charger (expansion system).
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Astralpool ASTRALPOOL HEAT II wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info