673158
11
Zoom out
Zoom in
Vorherige Seite
1/20
Nächste Seite
Inst.296 Viron eVo Series Pool & Spa Heater V07_16
12
600
Approved gas
termination cowl
1500
Upper grille for fresh air
ventilation
Lower grille for fresh air
ventilation
Do not install spa blowers in the same room as a gas heater. This is potentially dangerous to spa users.
Do not store chemicals or fuel in the same room as the gas heater. This may cause fire or explosion.
When installing in a garage the Viron Series Heater must be installed 450 mm above floor level.
ELECTRICAL CONNECTION
The heater is supplied with a standard 10 amp 3 pin plug for connection to a 240V 10 amp GPO. All pool or spa
equipment connected to mains power should be protected by an RCD circuit breaker.
GAS CONNECTION
The gas connection is on the right hand side of the heater. A 22mm M.I. connection is provided for gas line
connection. An approved manual shut off valve must be installed in the gas fitting line before the heater.
The gas fitting line should be installed by an authorised person and comply with local regulations and Australian
Standard code AS/NZ 5601. The gas line from the meter will usually be of a larger size than the gas inlet
connection.
The heater gas valve has a built in pressure regulator and ⅛” pressure test point. On starting the heater, a
manometer must be used and the supply inlet pressure checked while the heater is running against the heater
data plate. Incorrect inlet pressures may void warranty and may result in service charges, should service be
required. Gas valves are preset and should only be adjusted by trained Astral Pool technicians.
PRESSURE SWITCH ADJUSTMENT
The Viron Pool Heater incorporates a water pressure switch which allows the burner to operate only when the
circulating pump is operating. The pressure switch is designed to operate with the heater installed up to 1.2
metres above or below the surface level of the pool or spa. For installations outside these limits, a flow switch
should be installed.
It is imperative that the following be undertaken by the person who is commissioning (first starting) your pool or
spa heater. On initial start up of the heater it may be necessary to adjust the water pressure activation switch.
This switch is located behind the top right hand side panel and is screwed into the water manifold. The pressure
switch is a safety device, designed to allow operation of the heater only when the circulating pump is on and there
is sufficient water flow through the heater. It must shut the heater down immediately the pump is switched off.
To check the operation of the switch:
1. Connect the heater to mains power supply and turn power on. The thermostat should not yet display “θ”.
2. Turn on pump. The thermostat should now display “θ”.
3. Turn pump off. The thermostat should no longer display “θ”.
4. If display does not respond in this way, adjust the pressure switch as detailed below. If display responds
correctly, perform a final check with the heater operating.- See the section below titled “Starting the heater”
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Astralpool Viron eVo wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info