Page 28
HHCC
UUNNMMIIXXEEDD CCIIRRCC..
ECO
HHCC
jjEEDD.. HHEEAATTIINNGG
Reduced heating mode
Setting range: ECO, RED
Factory preset: ECO
Unmixed heating circuit (direct circuit)
This level includes the parameters required for programming
the heating circuit with the exception of the related operating-
times programs.
Entry: see » Programming level - Level summary « .
Exit: via button
¢¢
or automatically after 60 seconds
Modify: Confirm selected flashing parameter by pressing
the rotary-push button. Then set the new requi-
red value via and accept by pressing the rotary-
push button again. If necessary, correct the fol-
lowing parameters in the same way.
Application: Objects with high insulation values
Application: Objects with low insulation values
During the reduced operation the following modes can be selected:
ECO mode: At oudoor temperatures above the set plant frost
protection the heating circuit is switched off com-
pletely. At temperatures below frost protection the
heating circuit is controlled with reduced heating
characteristic according to the required reduced
temperature (see »Temperature setting« ).
RED mode: During the reduced mode the heating circuit pump
remains activated. The heating circuit is controlled
according to the reduced heating characteristic,
the temperature does not drop below the set mini-
mum temperature value.
Entry:
next parameter