4. Cut (#1) wire (as shown), and connect the ignition switch side of the cut wire to terminal #87a of the
relay. Connect the other side of the (#1) wire to terminal #30.
5. Connect the previously selected resistor from terminal #87 to the second (#2) wire (as shown).
NOTE: The above information and following diagram is for the GM VATS system only. For GM PASS LOCK
System you will require the Audiovox AS-PASS II Module.
DARK GREEN/ORANGE Wire: Tach Sensor Input
This wire will continually monitor the engine tach rate while the unit is under power of the Remote Start
module. This wire will be routed to the vehicle ECM tach input or through the firewall into the engine
compartment and connect to the negative side of the ignition coil. This Remote Start unit learns the tach
rate of the vehicle and in most cases will operate properly from one multi coil pack regardless of the number
of cylinders. If the vehicle has a single coil unit for each cylinder, it may be necessary to connect this wire
to more than one cylinder for proper tach reference. See multi coil wiring detail shown later in this manual
for additional information.
3 Pin Door Lock/Unlock Harness: (White Connector)
The Red & Green, Door Lock/Unlock output wires provide either a pulsed ground or pulsed + 12 volts to
control the vehicle door lock / unlock circuits. The Red/Black 2nd Unlock output wire provides only a
pulsed ground, and when used, must be wired as shown later on in this manual. The output of these wires
has a maximum switching capability of 300mA. Many vehicles today have factory door lock relays which
can be connected directly to these outputs. However, always confirm that the factory relays in your par-
ticular vehicle do not exceed the rated 300mA output of the units door lock/unlock/unlock 2 circuits. Plug
the three pin connector of the door lock/unlock harness into the mating connector shell of the control
module. Determine the door lock circuit of the vehicle you are working on and wire according to the
diagrams shown.
3 Wire Ground Switched Door Lock Circuits:
In this application, the Red wire of the door lock harness provides a ground pulse during locking or pulsed
ground lock output. Connect the Red wire to the low current ground signal wire from the factory door lock
switch to the factory door lock relay.
The Green wire of the door lock harness provides a ground pulse during the unlocking sequence, or
pulsed ground unlock output. Connect the Green wire to the low current ground signal wire from the
factory door unlock switch to the factory door unlock relay. See Below For Wiring Detail.
8
Tachometer Input Wiring Detail
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Audiovox Prestige Platinum APS 686T wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info