GB14
- Installation or maintenance must be carried out by a qualified technician.
The hood is designed for installation and use as an "Extractor version".
Install the hood away from very dirty areas, windows, doors and heat sources.
IMPORTANT:The hood comes with all the materials necessary for installation on the majority of ceilings.
To guarantee suitable installation, contact a qualified technician, a static load tester or an architect to make sure the materials used for the ceiling are suitable
for this type of installation.
Smoke is channelled outside through an exhaust pipe fixed to the connection flange. The diameter of the connection flange on the hood body and the motor is
150 mm. The diameter of the exhaust pipe must be at least 150 mm. Provide a fixing system suited to the connection flange.
IMPORTANT:The exhaust pipe is not provided and must be purchased separately.
ATTENTION:
MATERIAL SUPPLIED
INSTALLATION - PRELIMINARY ASSEMBLY INSTRUCTIONS
Take all parts out of their packaging and make sure all the listed components are included.
• Hood assembled with motor, metal filters and lamps installed.
• Remote control
• Assembly template
• 4 Plugs 10 X 60 mm
• 4 Screws 6 X 70 mm
• 4 Screws 4 X 7 mm
• 2 Screws 3 X 9 mm
• 1 connection flange Ø150 mm