Permitted natural gas connections itemised according to
countries:
Liquid gas connection (LPG)
Caution!
Follow country-specific guidelines.
If liquid gas (LPG) is used, the gas connection is established
via a gas hose or a fixed connection.
If a gas hose is used, pay attention to the following measures:
Use a safety hose or plastic hose (8 mm diameter).
Secure it to the gas connection with a connecting device (e.g.
a hose clamp).
The hose must be short and fully leakproof. The hose must
not be longer than 1.5 m. Pay attention to current guidelines.
The gas hose must be replaced annually.
Insert the safety hose and tighten using a screw coupling or
hose clamp.
Carry out a leak test once connection is complete. See the
section entitled "Leak test".
Conversion to a different gas type
Measures to note
The appliance may only be converted to a different gas type
by an approved specialist, in accordance with the
instructions in this manual.
Incorrect connection and incorrect settings may cause
serious damage to the appliance. The appliance
manufacturer accepts no liability for damage and
malfunctions of this kind.
Pay close attention to the symbols indicated on the rating plate.
If there is no symbol for your country, follow the technical
guidelines that apply in your country when making settings.
Before setting up the appliance, determine the gas type and
pressure in the local supply network. Before using the
appliance for the first time, make sure that all settings have
been made correctly.
Pay attention to local and international rules and regulations.
All connection data can be found on the rating plate on the rear
of the appliance at the bottom.
Enter the data in the following table:
Product number (E no.),
Manufacturing number (FD),
Enter the factory settings for gas type/gas pressure, as well as
the settings for gas type/pressure that apply after the gas
conversion, in the following table.
The changes made to the appliance and the type of connection
play an important role in ensuring that the appliance operates
correctly and safely.
Converting to a different gas type
The gas connection must be replaced.
The nozzles for the burners must be replaced.
Depending on the factory gas setting, the bypass nozzles in
the burner valves must either be replaced, or screwed in fully.
Numbers are printed on the nozzles indicating their diameter.
Further information about the gas types suitable for the
appliance, as well as the corresponding gas nozzles, can be
found in the section entitled "Technical properties - gas".
After the conversion
After the appliance has been converted to a different gas
type, you must perform a leak test. See the section entitled
"Leak test".
After the appliance has been converted to a different gas
type, you must check the flame behaviour. See the section
entitled "Correct flame behaviour".
Country
EN 10226 R
^
(TS 61-210 EN
10226 R
^)
EN ISO 228
G
^
(TS EN ISO
228 G
^)
AT Austria X
BE Belgium X
CH Switzerland X
DE Germany X
ES Spain X X
FR France X
GR Greece X
IT Italy X X
NL Netherlands/Holland X
PT Portugal X X
HR Croatia X
SL Slovenia X
YU Serbia X
TR Turkey X X
PL Poland X X
RO Romania X X
AE United Arab Emirates X
ZA South Africa X
HU Hungary X
RU Russia X
GB United Kingdom X
/3***
E no. FD no.
After-sales service
O
Type of gas / gas pressure
Data on the rating plate
Type of gas / gas pressure
Data after gas conversion
7

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Belion GK604ZB10 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Belion GK604ZB10

Belion GK604ZB10 Bedienungsanleitung - Englisch, Holländisch - 20 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info