BENNING MM 5-1/ 5-2
22
tion of the rotary switch position.
Switch position Function
Hz
Hz
Ω
Hz
°C ► °F
5.1.10 The nominal measurement rate of the BENNING MM 5-1/ MM 5-2 is 2
measurements per sec. for the digital display.
5.1.11 The BENNING MM 5-1/ MM 5-2 is switched on and off by the rotating
switch
. Switch-off position “OFF”.
5.1.12 The BENNING MM 5-1/ MM 5-2 switches off automatically after approx.
20 minutes (APO, Auto-Power-Off). It will switch on again as soon
as a key is pressed. Deactivate the automatic switch-off by press-
ing the function key (blue)
4
and simultaneously switching the
BENNING MM 5-1/ MM 5-2 ON from the switch position “OFF”.
5.1.13 Check the segments of the digital display by pressing the “Smart HOLD”
key
7
and simultaneously switching the BENNING MM 5-1/ MM 5-2
ON from the switch position “OFF”.
5.1.14 Temperature coefficient of measurement value: 0.1 x (stated measure-
ment accuracy)/ °C < 18 °C or > 28 °C relative to the value at the refer-
ence temperature of 23 °C.
5.1.15 The BENNING MM 5-1/ MM 5-2 is supplied by means of two 1.5 V micro
(AAA) batteries (IEC LR 03).
5.1.16 The battery display
3
permanently shows the remaining battery capac-
ity over a maximum 3 segments.
As soon as all segments in the battery symbol have gone off
and the battery symbol blinks please exchange the battery for
a new battery immediately in order to avoid a risk through false
measurements for people.
5.1.17 The life span of a battery is approx. 300 hours (alkali battery).
5.1.18 Appliance dimensions:
(L x W x H) = 138 x 68 x 30 mm without protective rubber holster
(L x W x H) = 150 x 77 x 44 mm with protective rubber holster
Weight:
180 g without protective rubber holster
310 g with protective rubber holster
5.1.19 The safety measuring leads are expressly suitable for the rated voltage
and power of the BENNING MM 5-1/ MM 5-2.
5.1.20 The BENNING MM 5-1/ MM 5-2 is protected against mechanical dam-
age by a protective rubber holster
M
. The protective rubber holster
M
allows to set up the BENNING MM 5-1/ MM 5-2 when making measure-
ments or to attach it by means of the integrated magnet.
6. Ambient conditions
- The BENNING MM 5-1/ MM 5-2 is designed only for measuring in dry sur-
roundings,
- Maximum barometric height during measurement: 2000 m.
- Overvoltage category / setting category: IEC 60664/ IEC 61010-1 600 V
category III; 300 V category IV.
- Degree of contamination: 2.
- Protection class: IP 30 (DIN VDE 0470-1 IEC/ EN 60529).
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 - first index). No protec-
tion against water, (0 - second index).
- Operating temperature and relative humidity:
At operating temperatures of 0 °C to 30 °C: relative humidity under 80 %.
At operating temperatures of 30 °C to 40 °C: relative humidity under 75 %.
- At operating temperatures of 40 °C to 50 °C: relative humidity under 45 %.
- Storage temperature: The BENNING MM 5-1/ MM 5-2 can be stored at
temperatures from - 20 °C to + 60 °C (humidity 0 up to 80 %). The batteries
must be removed from the unit.
21

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning MM 5-2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info