577356
33
Zoom out
Zoom in
Vorherige Seite
1/71
Nächste Seite
01/ 2015
BENNING ST 725
24
- Test certificate forms for "Testing of electrical devices" are available for download free of
charge at www.benning.de
Seegure10: Optionalaccessories
4. Unit description
Seegure1: Appliancefrontface
Seegure2: Topsideofthedevice
ThedisplayandoperatorcontrolelementsspeciedinFig.1and2aredesignatedasfollows:
1
Test socket, for connecting the device to be tested,
2
-key, testing of devices of protection class I (devices with protective conductor and
accessible conductive parts which are connected to the protective conductor),
3
-key, testing of devices of protection class II (shock-proof devices without protective
conductor and with accessible conductive parts) and testing of devices of protection class III
(safety extra-low voltage),
4
-key, testing the protective conductor current (differential measurement) or contact
current (direct measurement) under operating conditions (test sample is supplied with mains
voltage)
5
-key, reducing the testing voltage to 250 V
DC
or 500 V
DC
for measuring the insulating
resistance
6
-key, testing of 30 mA RCDs
7
-key, testing of three-phase devices under operating conditions (044140, 044141)
8
Digital display, indicates the test progress and individual measuring results,
9
4 mm test socket, for connecting the test lead with alligator clip
J
IEC connector, for connecting the IEC power cord
K
Mains connection socket, for connecting the mains voltage (230 V, 50 Hz), for voltage
measurement at external shock-proof socket or for connecting the measuring signal cable of
the measuring adapter (16 A CEE adapter, three-phase, active (044140)/ 32 A CEE adapter,
threephase, active (044141))
L
Serial PS/2 port for optional printer BENNING PT 1 (044150)
-key, for storing the displayed measured values (display values)
-key, for calling stored measured values (display values)
-key, for printing the displayed or stored measured values by means of the printer
BENNING PT 1
USB interface (Micro-B socket), for connection of the USB connecting cable
5. General information
The BENNING ST 725 is intended for electrical safety tests according to DIN VDE 0701-0702,
DGUV Regulation 3 (former BGV A3) and ÖVE/ ÖNORM E8701.
Automatically,theBENNINGST725veriesthetypeoftheconnectedtestobjectandinforms
the user in case of incorrect selection of the testing procedure [
2
...
3
]: preset limiting values and
measuring results with "pass/ fail" information make it easier to evaluate the test.
- At full battery capacity, the BENNING ST 725 allows to carry out approx. 2,500 device tests.
- Appliance dimensions:
(LxWxH)=270x115x55mm
- Appliance weight: 1100 g
6. Ambient conditions
- The BENNING ST 725 is intended for making measurements in dry environment.
- Maximum barometric elevation for making measurements: 2000 m,
- Overvoltagecategory/settingcategory:IEC61010-1→300VcategoryII,
- Contamination class: 2,
- Protection class: IP 40 (DIN VDE 0470-1 IEC/ EN 60529)
IP 40 means: Protection against access to dangerous parts and protection against solid
impurities of a diameter > 1 mm, (4 - first index). No protection against water, (0 - second
index).
- EMC: EN 61326-1
- Operating temperature and relative humidity:
For operating temperatures from 0 °C to 30 °C: relative humidity less than 80 %
For operating temperatures from 31 °C to 40 °C: relative humidity less than 75 %
- Storage temperature: The BENNING ST 725 can be stored at any temperature within the
range of - 25 °C to + 65 °C (relative humidity from 0 to 80 %). The battery should be removed
from the instrument for storage.
7. Electrical specifications
Note:Themeasuringaccuracyisspeciedasthesumof
- a relative fraction of the measured value and
- a number of digits (i.e. counting steps of the last digit).
Thisspeciedmeasuringaccuracyisvalidfortemperatureswithintherangeof18°Cto28°C
and relative humidity lower than 80 %.
33

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Benning ST 725 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info