474161
43
Zoom out
Zoom in
Vorherige Seite
1/67
Nächste Seite
ENGLISH
5
Special functions and any other adjustment
possibilities of the garage door operator
5.1 Second opening position (airing position)
In the airing position a second opening position can be
freely programmed. The latter is switched by channel 2 of
the radio receiver. Terminal 20 (0 V) and 23 (impulse input
partial opening). Set DIP switch 7 (SCH2) to OFF.
5.1.1 Programming the second opening position (airing
position)
The operator is ready for use and the operator stands still.
Check again if the the guiding hitch is clutched in the
flange lock / belt lock (see figure 17).
1) Press the black button (for approx. 6 sec.) until the
lamp starts flashing. Allow to flash twice, then press
additionally the white button and press (for approx. 2
sec.) until the lamp quickly flashes twice. Then
release both buttons.
2) Now press the white operating button so that the
door can travel to its "Second opening" position. The
door moves as long as the white button stays pressed
(permanent contact). Once the button is released,
the door stops immediately. The next time the button
is pressed, the door travels in the opposite direction.
This procedure is repeated until the desired "Second
opening" position is reached.
3) Briefly press the black “learn” button. The operator
lighting is switched on. “Second opening position” is
now programmed.
5.2 Defined direction instructions
A defined direction option is adjustable through DIP switch
7 (SCH2).
1) radio channel 1 (terminal 20/21) = open – stop – open
etc.
2) radio channel 2 (terminal 20/23) = closed – stop –
closed etc.
3) Set DIP switch 7 (SCH2) to ON
5.3 Quick-opening function
The quick-opening function is selectable through DIP
switch 3 (SCH2). Thereby: up to 50 % higher opening
speed*.
1) Set DIP 3 (SCH2) to ON = quick-opening speed
2) Set DIP 3 (SCH2) to OFF = normal opening speed
* depending on the door
Note
The motor of the garage door operator is equipped with a
thermal overload protection. In case of 2-3 quick door runs in
“OPEN” position (max 40 sec.) within 2 minutes, this overload
protection reduces the door speed, i.e. the door travels in
direction “OPEN” and “CLOSED” have the usual speed. After a
rest period of 2 additional minutes, the next run in direction
“OPEN” is executed quickly.
ATTENTION: danger to life
This function is not to be selected for
tipping and swing doors, but only for
holohedrally closed sectional doors!
* Accessory, is not included in delivery!
Note
After changing the door speed the operator has to be newly
programmed!
5.4 Soft-stop
Soft-start is adjustable with DIP switch 4 (SCH2) before
reaching end-of-travel position “CLOSED”
1) Set DIP 4 (SCH2) to ON = 30 % soft-stop – up and
over door
2) Set DIP 4 (SCH2) to OFF = 50 % soft-travel speed
5.5 Short return to the position “door closed”
The short return to the position “door closed” is
adjustable with DIP switch 5 (SCH2), i.e. the slide moves
briefly to position “OPEN” when reaching “CLOSED” .
1) Set DIP 5 (SCH2) to ON = short return “long”
2) Set DIP 5 (SCH2) to OFF = short return “very short”
Note
If DIP5 is activated during the memorising process, the
following functions are activated:
1) DIP5 (SCH2) set to ON = Short return “very short”
2) DIP5 (SCH2) set to OFF = Short reverse deactivated
On each new memorising process this procedure has to be
repeated.
5.6 Automatic timer
With this function, the door is automatically closed after
a preset open phase has elapsed. According to EN 12453
Tab.1, this function is only permitted if combined with a
photocell.
Note
If the "automatic timer" is set, impulse operation is not
possible. Each command causes the door to open or
the open phase to be reset.
A closing from the position “partial opening” occurs only if the
distance to the end-of-travel position “door CLOSED” is
> 500 mm. In case of a smaller distance, the door has to be
closed by reoperating the button “partial opening”.
5.6.1 Programming the automatic timer / early warning
phase
The door must be at a standstill and ready for operation.
Briefly press the black "learn" button (lamp flashes five
times), wait till the desired open phase is over (min.
10 sec. to max. 150 sec.). Then briefly press the black
"learn" button, the lamp continues to flash five times. You
must now wait for the early warning phase to be set (min.
3 sec. to max. 30 sec.), then briefly press the black "learn"
button again. You have now activated the automatic timer.
In this mode the door can only be opened via radio and
button. If a command is given during the closing phase,
the door reverses and travels to its "OPEN" position.
Automatic closing only takes place from the "OPEN"
position provided no safety circuit has been broken and
the open phase has elapsed.
Note
If, on account of the overcurrent cutoff, the door has
reversed twice to its "OPEN" end-of-travel position, the
automatic timer will be blocked. The garage lighting signals
the impulse code for "twice safety device" and an
acknowledgement
via the button must be issued. The open phase
will not start running until this acknowledgement has been
issued.
43
43

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

berner-ga201

Suche zurücksetzen

  • Hallo
    Habe einen Garagentorantrieb von Berner. GA201.
    Der Handsender ist verloren gegangen. Berner hat mir den BHS 120 und später den BHS121 zugeschickt. Beide funktionieren nicht. Kann mir da jemand weiterhelfen? Eingereicht am 25-11-2022 09:14

    Antworten Frage melden
  • Hallo, habe das Garagentor Berner GA 201 /V2.
    Nun habe ich einen neuen Handsender RCBE 868 gekauft und finde leider weder hier noch im Internet die Anleitung, wie der Handsender am Empfänger programmiert werden kann.
    Wäre über eine kurze Hilfestellung sehr dankbar.
    Grüße
    G. Maneth Eingereicht am 12-6-2019 21:00

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Berner GA201 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info