CHANGING LIGHT BULBS
Bielmeier extractor hoods are supplied with LED lights. Lightbulbs are wear parts and can be ordered from the
manufacturer on demand as spare parts.
However, the use of LEDs as workstation lights makes the need to replace defective lights highly unlikely. Service
life, reliability, and energy efficiency are significantly above those of conventional lightbulbs, such as halogen,
fluorescent tubes, etc. However, proceed as follows if the lights nevertheless fail:
Changing LED lightbulb
Pull power plug and/or disable circuit breaker!
In order to reduce dirt buildup in the hood interior, the LED spotlights for the workstation lighting are mounted
flush with the hood body.
1. Open the cover plate and remove the grease filter.
2. Now push the complete LED spotlight from the interior to the outside.
3. Disconnect the connector for the defective spotlight.
4. Connect the new spotlight with the connector.
5. Then gently push the spotlight back into the housing.
NOTE: If the lights fail to work, check whether the lights are seated properly. Defective lights should be replaced
promptly to avoid overloading the remaining lights.
Contact customer service if the lights do not work after the lightbulbs were replaced.
STARTUP – OPERATION
Operator panel - electronic control: BHG52, BHG53, BHG59, BHG58
Lighting Output Output Display Output Dwell Timer Operator
Controls increase decrease remotecontrol
on / off
The operator panel is located on the front of the equipment. It has a user-friendly design and is easy to operate.
Operator panel - electronic control: BHG41
Operator controls Lighting Output
Remote control on / off
Dwell timer Output display Output Blower
decrease on / off
Operator panel - electronic control: BHG39, BHG93
Operator control Blower on/off Dwell timer
Remote control
Output display Output Output Lights
on/off
Operator control / remote control
This unit can also be conveniently controlled with the included IR remote control:
Electronic control
Lights on/off
The lights are switched on or off by touching this control surface.
When is touched (increase output)
a „5 or F5“ is displayed in the output display. This means: the highest output level is automatically selected when
this control surface is pressed. The output level is continuously incremented up to the highest output level when
the control surface is depressed continuously.
GB
17

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bielmeier BHG39 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info