into, weld, or make an y modifications to the
inflator or its attachments.
Do not operate the inflator when the engine is •
running.
Operate only with the accessories included or •
those rated for 8.27 bar/120 psi or higher . The
us e o f any acc es sory n ot re com me nde d for u s e
with this tool could be hazardous.
Do not play with the tool. High pressure air is •
dangerous. Do not direct air -flo w at yourself or
others.
Th e i nfl ator ca n bec om e h ot du ri n g us e. A ll ow •
the inflator to cool for 30 minutes before storing
away .
Never carry the infla tor by the hose.•
Do no t dir ec t t he no zz l e or ho se at ani ma ls or •
bystanders.
Store the inflator out of reach of small children.•
The gauge is intended as a guide only . T yre •
pr e ss ur es sh oul d be re g ul ar ly ch eck ed wi th a
certified gauge.
Before use, check the power supply cord for •
signs of damage, ageing and wear .
Do not use the appliance if the power supply cord •
or ma in s p lu g i s dam ag ed o r d ef ect iv e ( wh ere
applicable).
Electric Safety
If th e 12V p ower co rd is d amag ed, i t m us t b e rep la ced
by th e man uf act ur er , au th o ri ze d B la ck & Dec ke r
Se rv ic e Cen te r o r an eq ual ly qu al i fie d per so n i n ord er
to avoid damage or injur y . If the power cord is replaced
by an equally qualified person, but not authorized by
Black & Decker , the warranty will not be valid.
Labels on tools
The following pictograms are shown on the tool:
Features
Area light1.
Pressure gauge2.
Storage location for air hose and 12 V olt adaptor3.
Air hose with universal valve adaptor4.
On/off switch5.
12 Volt adaptor6.
Area light on/off switch7.
Use
Air hose and cord storage (fig. A)
W r ap t h e dc c o rd a r o un d t he b a s e of t he u n it a n d t he n pu t
t h e a i r h o s e ( 4) a nd t h e 1 2 V o l t a d a p t or ( 6 ) i n t o t he s to ra g e
location (3).
Fitting the accessories (fig. B and C)
Y o ur i nfl at or i s su p p li e d wi th t he s t a nd a r d t ap er e d n o z z le s
a n d t h e n e e d le i n fl at or n o zz le , th es e ar e l oc at ed o n t h e
base of the unit (fig. C).
T o use the universal valve adaptor , make sure •
that the lever is in the up position.
Pl a ce t he va lve a dapt er ov er th e s te m o f the •
inflation needle or tapered nozzle (fig. B).
Press the lever on the valve adapter down to lock •
it in place.
Pl a ce t he in flati on ne edl e or ta pe re d n oz zle i nto •
the item to be inflated.
Note: Al wa ys ma ke su re th at t h e le ver i s i n the u p
position when not in use.
Op e rat e y ou r I nfl ator on ly wi th th e uni ve r sa l val ve
adaptor or with the included nozzles.
Note: Make sure that the universal valve adaptor is
firmly locked in place before turning the Inflator on.
Ma ny i nflat abl es hav e a n int er nal fl ap t hat pre ve nts
air loss during inflation. Unless this flap is displaced
by th e noz zl e t he in fla ta bl e w il l n ot in fla te . P us h t he
nozzle firmly into the valve to make sure that you push
this flap out of the way .
St o re t he in flati on ne edl e ins id e o ne of t he ta pe r ed
no z zl es an d snap th e tape red n ozz le s i nt o t he st or age
slots located on the bottom of the Inflator (fig. C).
Warning! E x ce ss ive a ir pr ess ur e m ay ca us e a
hazardous risk of bursting or personal injury . Check the
manufacturer’ s maximum pressure rating for the items
being inflated.
No t e: I f t he pr es sur e r ati ng fo r t he it em be in g i nfl ated
is ab ov e 1 00 ps i, no te th at t he ma x im um ru n tim e
is 10 m inu te s, le ave to re st fo r 2 0 min ut es be for e
re-use.
Operating the inflator
Warning! Do not operate the inflator when the car
engine is running.
Note: M ak e sur e that yo ur 12 V ol t acc es sory s ock et
is li ve . O n s om e v eh ic le s t he ac ce sso ry soc ke t m ay
on l y be com e liv e whe n t he i gni ti on ke y i s in th e
accessory position.
T o power the display
Always fully extend the 12 Vdc cord before each •
use.
Co n ne ct th e 12 V o lt a dapt or (6 ) i nt o t he ve hi c le’ s •
12 Volt accessory socket.
T o enable the inflator to operate you must •
se t t he re qu ire d uni ts (p si , b a r or kP a) and a
pressure valve.
Setting the required pressure (fig. D)
Warning! Do not leave the inflator running
unattended. It could burst tires or other items.
Note: Y ou m us t set t he au tom at ic sh ut -of f feat ure
before the unit will operate.
T o sw it ch be tw een t he di ffe re nt un i ts ( kP a, ps i or •
ba r ), p res s but to ns 8 & 9 a t the s ame t i me u nti l
the required units are displayed.
Press and hold button 8 or 9 for 3 seconds until •
the display flashes.
While the display is flashing press the - or + •
bu t to ns (8 & 9) u nti l t he r equ ir ed pr ess ur e i s
displayed.
Af t er 3 se co nds t he di s pl ay wi ll fla sh an d ret ur n •
to a reading of “0.0”. This is normal.
Co n ne ct th e uni ve rsa l v al ve ad ap to r a nd •
accessories, if required, to the item to be
in fl ate d, ma kin g sur e that th e lev er of t h e va lve
adaptor is in the down position to lock it in place.
T o tu rn th e infl at or on , p re ss th e on/ of f sw itc h (5) •
to the I position.
When the item to be inflated has reached the •
preset value the unit will automatically turn off.
T o turn the inflator off press switch (5) to the 0 •
position.
Re m ov e the v alv e adap tor o r a cc e ss ory fr om th e •
inflated item and the 12 V olt ada pter (6) from
your vehicle’ s 12 Volt accessory socket.
Note: I f th e 1 2 Vo lt ad ap te r i s rem ov ed fr om th e
vehicles 12 Volt accessory socket, all settings will
be lost and will need to be re-entered following the
instructions under the heading ‘Setting the required
pressure.
Operating the area light
T o operate the area light (1), make sure that the •
12 Volt adaptor (6) is plugged into the vehic le’ s
12 Volt accessory socket.
Note: Ma k e su re th at y our 1 2 Vo l t ac ces so ry s oc ket
is li ve . O n s om e v eh ic le s t he ac ce sso ry soc ke t m ay
on l y be com e liv e whe n t he i gni ti on ke y i s in th e
accessory position.
T o turn the area light on, press the area light on/•
off switch (7) located on the side of the unit to
the I position.
T o turn the area light off, press the area light on/•
off switch (7) located on the side of the unit to
the 0 position.
T o replace the bulb (fig. E)
Warning! Make sure that the 12 Volt adaptor is not
connected before starting this procedure.
Remove the screw (10) from the top of the lens cover •
(12).
P u l l t h e l e n s c o v e r ( 1 2 ) d o w n u s i n g t h e t a b ( 1 1 ) t o g e t •
access to the bulb (13).
T o remove the bulb, push in and turn clockwise (fig. E).•
R e p l a c e t h e b u l b ( 1 3 ) w i t h a o n e o f t h e s a m e t y p e a n d •
wattage (12V/5W).
Fit the lens cover (12) and secure with the screw (10).•
Using your inflator as a pressure gauge
Make sure that the unit is powered as described •
in the section ‘Operating the Inflator’.
Co n ne ct th e uni ve rsa l v al ve ad ap to r a nd •
accessories if required to the item to be inflated
ma k in g sur e that th e lev er of t h e va lve a dapt or is
in the down position to lock it in place.
The display will now show the actual pressure •
value in the item.
Maintenance
Y ou r B la ck & De cke r cor de d/c or d le ss app lia nc e/t oo l
ha s b ee n d es ign ed to o p er at e ove r a l on g p er iod o f
ti m e wi th a min im um of ma in ten an ce. C ont in uou s
ENGLISH ENGLISH
Warning! T o reduce the risk of injur y , the user
must read the instruction manual.
Do not expose the appliance to rain or high
humidity
Before performing maintenance or cleaning on
the appliance, unplug the supply cord.
Do not leave the inflator unattended.