1 609 92A 0XB | (17.12.14) Bosch Power Tools
Extraction of dusts resulting from running power tools
(see figure G)
An adequate ventilation rate (L) must be provided for
when the outgoing air is circulated. Observe the re-
spective national regulations.
A socket outlet with earthing contact 4 is integrated in the
vacuum cleaner. An external power tool can be connected
there. Observe the maximal allowable load of the connected
power tool.
Mount the tool sleeve 20 (see “Mounting the Tool Sleeve”,
page 19).
Insert the tool sleeve 20 into the vacuum connection of the
power tool.
To start the vacuum cleaner’s automatic
Start/Stop feature, set the mode selector
switch 6 to the “Automatic Start/Stop” sym-
bol.
–To start the operation of the vac, switch on the power tool
connected to the socket 4. The vacuum cleaner starts au-
tomatically.
Switch the power tool off to end the vacuuming.
The delayed action shutdown of the Automatic Start/Stop
continues to run for up to 15 seconds in order to extract re-
sidual dust from the vacuum hose.
To switch the vacuum cleaner off, set the mode
selector switch 6 to the “Off” symbol.
Wet Vacuuming
Do not vacuum inflammable or explosive fluids; for ex-
ample, benzene, oil, alcohol, solvents. Do not vacuum
hot or burning dust. Do not operate the machine in
rooms where the danger of an explosion exists. The
dusts, vapours or fluids can ignite or explode.
The vacuum cleaner may not be used as a water pump.
The vacuum cleaner is intended for vacuuming air and wa-
ter mixtures.
Before any work on the vacuum cleaner itself, pull the
mains plug.
Note: The requirements for the ingress degree (dust
category L) have only been proven for dry vacuuming.
Remove the disposal bag 23 or the dust bag and empty the
container 1 before wet vacuuming.
Note: For easier disposal when vacuuming liquid-solid mix-
tures, use a wet filter bag (accessory), which separates liq-
uids from solids.
Mount the rubber lips into the floor nozzle (see “Inserting
the Rubber Lip”, page 19).
Switch the automatic filter cleaning (AFC) off (see “Deacti-
vating the AFC”, page 20).
The vacuum cleaner is equipped with filling-level sensors 35.
When the maximum filling height is reached, the vacuum
cleaner switches off. Set the mode selector switch 6 to the
“off” symbol.
Note: When vacuuming non-conductive liquids (e. g. drilling
emulsion, oil and grease), the vacuum cleaner is not switched
off when the container is full. The level must be monitored
continuously and the container emptied in time.
To prevent the formation of mould after wet vacuuming:
Take out the flat-fold filter 24 and allow it to dry well.
Remove the vacuum cleaner lid 10 open the filter cover 34
and allow both components to dry thoroughly.
Filter Cleaning
Automatic filter cleaning (see figure H)
In automatic filter cleaning mode (AFC = Automatic Filter
Cleaning), the flat-fold filter 24 is cleaned every 15 seconds
by means of air blasts (pulsating noise).
The filter cleaning system must be actuated at the latest when
the vacuuming performance is no longer sufficient.
Regular use of the filter cleaning feature increases the tool life
of the filter.
To achieve ideal filter tool life, deactivate the automatic filter
cleaning in exceptional cases, e. g., when vacuuming pure liq-
uids or when working with a paper filter bag.
A flat-fold filter contaminated only on the surface is fully func-
tional. Manual cleaning of the flat-fold filter by striking/tap-
ping against it or blowing it out is not necessary, and can even
damage the filter.
Note: The automatic filter cleaning is factory-set.
Switching the automatic filter cleaning on/off is only possible,
when the VAC is running.
Deactivating the AFC
Actuate the AFC button 3.
The signalling LED 33 goes out.
Activating the AFC
Actuate the AFC button 3.
The signalling LED 33 lights up green.
Maintenance and Service
Maintenance and Cleaning
Before any work on the vacuum cleaner itself, pull the
mains plug.
For safe and proper working, always keep the vacuum
cleaner and ventilation slots clean.
Wear a dust protection mask when maintaining and
cleaning the vacuum cleaner.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
A dust-technical inspection is to be carried out at least once
every year by the manufacturer or an instructed person, e. g.
for damage of the filter, tightness against leakage of the vacu-
um cleaner and function of the control/monitoring unit.
For category L vacuum cleaners that were in contaminated
environments, the exterior as well as all machine parts should
be cleaned or treated with sealants. When performing mainte-
nance and repair work, all contaminated components that
cannot be cleaned to satisfactory must be disposed of. Such
components must be disposed of in impermeable plastic bags
conforming with the valid regulations for the disposal of such
waste.
OBJ_BUCH-1746-003.book Page 20 Wednesday, December 17, 2014 2:07 PM
20

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GAS 35 L AFC Professional wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info