(32) Parallel guide/guide rail adaptera)
(33) Pair of screw clampsa)
(34) Guide raila)
a) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical data
Hand-held circular saw GKS 12V-26
Article number 3 601 FA1 0..
Rated voltage V 12
No-load speed rpm 1400
Max. cutting depth
at a 0° mitre/bevel angle mm 26.5
at a 45° mitre/bevel angle mm 17.0
Spindle lock
Base plate dimensions mm 167 x 88
Max. saw blade diameter mm 85
Min. saw blade diameter mm 85
Max. base blade thickness mm 0.7
Max. tooth thickness/offset mm 1.1
Min. tooth thickness/offset mm 1.0
Locating bore mm 15
Weight according to
EPTA-Procedure 01:2014 kg 1.3–1.6A)
Permitted ambient temperature
during charging °C 0 to +45
during operationB) and
during storage °C -20 to +50
Recommended batteries GBA 12V...
GBA 10.8V...
Recommended chargers GAL 12..
AL 11..
A) Depends on battery in use
B) Limited performance at temperatures <0°C
Noise/Vibration Information
Noise emission values determined according
toEN62841-2-5.
Typically, the A-weighted noise level of the power tool is:
Sound pressure level 82dB(A); sound power level
93dB(A). Uncertainty K=3dB.
Wear hearing protection
Total vibration values ah (triax vector sum) and uncertainty K
determined according toEN62841-2-5:
Sawing wood: ah<2.5m/s2, K=1.5m/s2
The vibration level and noise emission value given in these
instructions have been measured in accordance with a
standardised measuring procedure and may be used to com-
pare power tools. They may also be used for a preliminary
estimation of vibration and noise emissions.
The stated vibration level and noise emission value repres-
ent the main applications of the power tool. However, if the
power tool is used for other applications, with different ap-
plication tools or is poorly maintained, the vibration level
and noise emission value may differ. This may significantly
increase the vibration and noise emissions over the total
working period.
To estimate vibration and noise emissions accurately, the
times when the tool is switched off or when it is running but
not actually being used should also be taken into account.
This may significantly reduce vibration and noise emissions
over the total working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping their hands warm,
and organising workflows correctly.
Fitting
uOnly use saw blades the maximum permitted speed of
which is higher than the no-load speed of the power
tool.
Battery Charging
uUse only the chargers listed on the accessories page.
Only these chargers are matched to the lithium-ion bat-
tery of your power tool.
Note: The battery is supplied partially charged. To ensure
full battery capacity, fully charge the battery in the charger
before using your power tool for the first time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
does not damage the battery.
The lithium-ion battery is protected against deep discharge
by the "Electronic Cell Protection (ECP)". When the battery
is discharged, the power tool is switched off by means of a
protective circuit: The application tool no longer rotates.
uDo not continue to press the On/Off switch after the
power tool has automatically switched off. The battery
can be damaged.
Follow the instructions on correct disposal.
Removing the battery
The battery (1) is equipped with two locking levels to pre-
vent the battery from falling out if the battery release button
(2) is pressed unintentionally. As long as the battery is inser-
ted in the power tool, it is held in position by means of a
spring.
To remove the battery (1), press the release button (2) and
pull the battery to the rear and out of the power tool. Do not
use force to do this.
Battery Charge Indicator
The three green LEDs of the battery charge indicator (15) in-
dicate the state of charge of the battery (1). For safety reas-
1 609 92A 7TA | (17.05.2022) Bosch Power Tools
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Bosch GKS 12V-26 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info