THUNDER BAY SE
ISSUE POSSIBLE CAUSE SOLUTION
No power Breaker or RCD off Check that RCD breaker is turned ON
Loose wire connection Check wire connections
RCD trips Mis-wired Check wiring per diagram, especially neutral wire
Component failure Perform elimination test to determine failed component. See
elimination test section
Heater not operating or spa not Improper voltage to heater At power up, verify voltage to heater by observing the last
heating numbers displayed on Topside Console:’12’ for 110-120 volt
spas or ‘24’ for 230-240 volt spas
Set on ECON or SLP mode Reset to STD
Temperature set to low Set temperature above current water temperature
Water level too low Add water until water level is 1 inch (25mm) above Water Line
Blown fuse Check 30amp bus fuse on control board
Component failure Contact dealer
Pump not operating or turns off Air lock See Air lock procedure
after a short time Improper voltage to pump Contact dealer or qualied electrician
Time out As a safety precaution, the Spa Controller only allows Pump
operation for 15 minutes continuously
Component failure Contact dealer or qualied electrician
Thermal overload During extreme high ambient temperatures the pump motor may
reach the motor thermal overload limit. Wait until motor cools
and retry. If problem persists contact dealer
• Pump surging Low water level Add water until water level is 1 inch (25mm) above water line
• Light will not turn on Burned out bulb Change bulb
Light bulb may have fallen out Unscrew back housing and reinsert bulb
Ozone Generation Unit will not Blown fuse Check Ozone fuse
operate Burned out UV bulb Replace unit
Component failure Contact dealer
No water Flow from Jets Air lock See air lock procedure
Adjustable jets turned off Turn jets on
Faulty pump or motor Contact dealer
Slice valve closed Open slice valve
Clogged lter Clean or change lter
Jet popped Out Jet face not seated Insert jet and turn clockwise until jet snaps into place you will
feel the jet seat
Broken jet Contact dealer
No air ow from jet Adjustable jets turned off Turn jets on
Air control valve not open Open air control valve
Broken jet Contact dealer
Jet not seated properly Insert jet and turn clockwise until jet snaps into place as it seats
Noisy Pump or Motor Air lock See air lock procedure
Low water level Add water until water level is 1 inch (25mm) above water line
Clogged lter Clean or replace lter
Damaged or warn motor bearings Contact dealer
Spa Overheating High ambient temperature During extreme high ambient temperatures the spa may over
heat due to internal friction with in the plumbing. Reduce set
temperature or remove spa cover to cool.
Filtration duration Reduce ltration cycle duration to minimum setting
Spa will not turn off Spa is trying to heat Check set temperature or heat indicator light on topside console
is ON
Spa is on high lter cycle Check lter cycle and reduce to 2 or 4
Spa is in standard mode See spa modes section
Abnormal water Excessive evaporation Check and adjust spa cover if needed
Excessive splashing Monitor water level after each use
Water not clean Dirty or clogged lter Clean or replace lter
Poor water chemistry See common water problems section
Insufcient ltration Cycle duration Based on usage ,adjust ltration cycle duration
High solids content See common water problem section
Trouble shooting
(16)
16

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Canadian Spa Company Thunder Bay SE - KH-10030 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info