08 GB- IE
ATTENTION:
should it be necessary to replace the supply cord, connect the wire
in accordance with the following colours/codes:
BLUE - NEUTRAL (N)
BROWN - LIVE (L)
YELLOW-GREEN - EARTH ( )
The hob is fitted with a power supply cord which allows it to be
connected only to a power supply of 220-240 V between phases
or between phase and neutral.
. Connect to a socket.
It is however possible to connect the hob to :
. Three phase 220-240 V3~
. Three phase 380-415 V2N~
To proceed to the new connection, you must adhere the
following instructions.
- Before making the connection, make sure that the installation is
protected by a suitable fuse, and that it is fitted with wires of a
large enough section to supply the appliance normally.
- Turn over the hob, glass side against the work top, taking
care to protect the glass.
Open the cover in the following sequence:
1 2 3
. unscrew the cable clamp "1",
. find the two tabs located on the sides,
. put the blade of a flat screw-driver in front of each tab "2" e "3",
push in and press,
. remove the cover.
To release the power supplying cord.
. remove the screws retaining the terminal block which contains
the shunt bars and the conductors of the supply cord,
. Pull out the supply cord.
Operations to be carried out to make a new connection :
- Choose the power supply cable in accordance with the
recommendations in the table.
- Pass the power supply cable into the clamp.
- Strip the end of each conductor of
the supply cord on a 10 mm length,
by taking in account the requested
length of the cord for the connection
to the terminal block.
- According to the installation
and with the help of shunt bars which
you should have recovered in the
first operation, fix the conductor as
shown on the chart.
- Fix the cover.
- Screw the cable clamp.
Note: make sure the terminal board screws are tight.
SHUNT
Connection to the terminals on the terminal block
LAY OUT
“ 3 ”
LAY OUT
“ 2 ”
Cable
HO5V2V2F
3x2,5
3x2,5 3x2,5
Cable
HO5V2V2F
4x1,5
4x1,5 4x1,5
Cable
HO5V2V2F
4x1,5
4x1,5 4x1,5
LAY OUT
“ 1 ”
N = Neutral T = Earth
Monophase 220-240 V~
Two phases 220-240 V2~
Three phases 220-240 V3~ Three phases 380-415 V2N~
5. PRESENTATION
• hilight zone :
a metallic conductor strip is spread uniformly over the whole
surface unit. It is effective within 3 seconds and is suitable for
steady, homogeneous and also sustained cooking.
The glass-ceramic hob benefits from greater heat output which is
generated by the hilight cooking zones thereby accelerating the
cooking process. Modifications to the design of the hob have not
affected the capacity of the glass to withstand high temperatures,
but they have improved controllability.
With the "Sprinter" facility, reduced cooking times of up to 15% can
be achieved, depending upon the method of cooking and the type
of saucepans being used.
6. HOB COOKWARE ADVICE
Using good quality cookware is critical for setting
the best performance from your hob.
Always use good quality cookware with perfectly flat and
thick bases :
using this type of cookware will prevent hot spots that cause
food to stick. Thick metal pots and pans will provide an even
distribution of heat.
Ensure that the base of the pot or pan is dry : when filling
pans with liquid or using one that has been stored in the
refrigerator, ensure that the base of the pan is completely dry
before placing it on the hob. This will help to avoid staining the
hob.
Use pans whose diameter is wide enough to completely
cover the surface unit : the size of the pan should be no
smaller than the heating area.
If it is slightly wider the energy will be used at its maximum
efficiency.
Ph = Phase